Item
Measuring
instruments
Test point
Adjustment part
Description
V.SIZE
Adjustment
Signal
generator
No.13 V.SIZE
1. Receive a crosshatch signal.
2. Select No.13 V SIZE in the PICTURE MODE.
3. Set the initial setting value of No.13 V SIZE with the LEFT /
RIGHT key of the MENU.
4. Adjust No.13 V SIZE until the vertical screen size is 92%.
H.POSITION
Adjustment
Signal
generator
No.15 H POS.
1. Receive a crosshatch signal.
2. Select the No.15 H POS. of the PICTURE MODE.
3. Set the initial setting value of the No.15 H POS. with the LEFT /
RIGHT key of the MENU.
4. Adjust the No.15 H POS. until the screen will be horizontally
centered.
Screen size
Picture size 100%
Screen
size
92%
Picture
size
100%