Item
Measuring
instrument
Test point
Adjustment part
Description
Adjustment
of DELAY
POINT
(AGC)
Signal
generator
Remote
control unit
DELAY POINT
(AGC TAKE-OVER)
1. Input a black and white signal (colour off).
2. Select
1. IF
from the SERVICE MENU.
3. Select
2. DELAY POINT
by pressing the
2
key on the remote
control unit.
4. Set the setting values of the setting items as shown bellow
table.
5. Then adjust the MENU - or + key until video noise disappears.
6. Turn to other channels and make sure that there are no
irregularities.
Setting Item
Variable range
Initial setting value
NTSC 3.58
48
DELAY POINT
(AGC TAKE OVER)
OTHER
0
~
127
43
DELAY POINT UHF
AGC TAKE-OVER
**
- / + : OPERATE DISP : EXIT