background image

13

www.juwent.com.pl

III. WARRANTY TERMS AND CONDITIONS

1.  JUWENT Szymański, Nowakowski General Partnership, headquartered in Ryki at 31 Lubelska Str., hereinafter referred to as the 

Warrantor, grants the Customer a warranty of proper operation of the unit with reservation of the requirement of its use in accordance 

with the conditions determined in the instruction manual and the terms and conditions specified below.

2.  The warranty has been granted for a period of 24 months from the purchase date demonstrated in this warranty document with 

a possibility of its special extension according to a separate agreement and specified in the Special Warranty Terms and Conditions.

3.  The warranty covers the removal of technical defects of the unit arisen as a result of its use in accordance with the instruction 

manual, revealed within the warranty period. The warranty provisions are valid in the territory of the Republic of Poland.

4.  By virtue of the granted warranty the Warrantor is not liable for the loss of expected profits and costs resulting from a periodical 

impossibility of the use of the unit incurred by the Customer.

5.  To realize the Customer’s rights resulting from the warranty it is required to deliver the claimed unit with the warranty document 

to the Warrantor at his expense.

6.  The claimer delivers the unit in an original factory packing, in case there is no factory packing the claimed unit should be delive-

red by the Customer for the repair in a way ensuring a safe transport. The risk of accidental damage of the unit during the transport 

burdens always the party that dispatches the parcel.

7.  The defects revealed with the warranty period will be removed by the Warrantor free of charge. A method selection of the reali-

zation of obligations resulting from the warranty granted to the Customer belongs to the Warrantor that may remove a defect by the 

repair or the replacement of the damaged subassembly or by the replacement of the unit. The property of the unit withdrawn from 

service and / or defective subassemblies is transferred to the Warrantor.

8.  The warranty is extended by a period for which the Customer has been deprived of a possibility to use the unit.

9.  The Warrantor will make efforts that the repair is executed without further delay within the time-limit of up to 14 working days 

from the delivery date of the unit. In reasonable cases of which the Customer will be informed by the Warrantor, this time-limit may 

be extended, e.g. by the time of provision import or when there is a necessity to execute an expertise or laboratory tests in specialized 

institutions.

10.  The Warrantor is liable exclusively for the defects inherent in the sold unit. The damages arisen after its sale for other reasons are 

not covered by the warranty, in particular:

a)  mechanical damages (including also damages caused by microparticles occurring in the working environment of the unit), 

thermal damages, chemical damages and aleatory damages or damages caused by the atmospheric factors,

b)  damages occurred as a result of non-observance of typical rules or the rules required by the instruction manual related to the 

operation and mounting of the unit or the use of the unit against the intended use and other damages caused by the Customer’s 

activity or omission,

c)  damages being a result of defective operation of the system in which the unit has been built or used,

d)  damages occurred as a result of non-execution of the actions to which the Customer has been obliged in accordance with the 

instruction manual, e.g. periodical cleaning, maintenance, adjustment, etc.,

e)  damages occurred due to the use of materials or parts subject to a normal operational wear other than the materials recom-

mended by the Warrantor in the instruction manual,

f)  damages being a result of use of power supply of the unit (of the system in which this unit functions) incompliant with the 

standard, and in case the unit is also supplied with water, damages being a result of use of water (supply water and / or boiler 

water) with parameters other than the parameters foreseen in the valid standard (PN-93/C-04607),

g)  damages occurred as a result of operation and / or maintenance of the unit in a way incompliant with the instruction manual 

and / or executed by the unauthorized persons.

11.  The warranty does not cover as well:

a)  activities executed by the Customer in accordance with the recommendations included the instruction manual of the unit within 

the framework of normal maintenance and inspections,

b)  travel and work costs of the Warrantor’s service or an entity delegated by the Warrantor in case when a warrant call turns out 

to be groundless.

12.  An annotation made by a trained employee in the Inspection and Maintenance Document of the unit is a confirmation of time-

-limit holding and range of activities foreseen for the maintenance of the unit.

13.  The Warrantor is not liable for damages incurred by the Customer or third parties caused the run of the unit occurred in particular 

as a result of non-observance of the afore-mentioned terms and conditions by the Customer.

14.  In case the service works are executed by the Warrantor at the place where the unit is mounted, the Customer will make available 

a free access to the rooms where the units are located to the Warrantor.

15.  In case the units are mounted at the height making an access from the floor surface impossible, the Customer will ensure the 

scaffolding compliant with the OHS regulations or mobile lifting platforms and vertical transport equipment.

16.  The equipment from the electric and / or hydraulic system is disassembled by the Customer.

17.  The claims should be lodged at the Warrantor’s address in writing / by fax / email using a service notification form.

18.  The Warrantor refuses to execute the warranty activities (periodical service works or repair) in case the price for the unit or pre-

vious service work is not paid for the benefit of the Warrantor.

DATE OF SALE

STAMP AND SIGNATURE

Special Warranty Terms and Conditions:

Warranty period extension up to ........... months.

Other:

STAMP AND SIGNATURE

Содержание AGE-1-3

Страница 1: ...ne 48 81 883 56 00 fax 48 81 883 56 09 POLAND I CONTACTS II ORIGINAL INSTRUCTION MANUAL III WARRANTY TERMS AND CONDITIONS IV UNIT STARTUP REPORT V INSPECTION AND MAINTENANCE DOCUMENT VI SERVICE NOTIFICATION Please read this instruction manual carefully before beginning any work RYKI 2015 ISSUE 1 EN ...

Страница 2: ... com pl I CONTACTS Szymański Nowakowski General Partnership 31 Lubelska Str 08 500 Ryki phone 48 81 883 56 00 fax 48 81 883 56 09 POLAND Export department mob 48 502 087 841 mob 48 664 465 243 export juwent com pl ...

Страница 3: ...3 www juwent com pl ELECTRIC HEATING UNITS AGE size 1 6 II ORIGINAL INSTRUCTION MANUAL ...

Страница 4: ...ATIONS 5 3 DEVICE DESCRIPTION 5 4 TECHNICAL DATA 6 5 TRANSPORT 6 6 SAFETY RECOMMENDATIONS 7 7 INSTALLATION 8 8 ELECTRICAL INSTALLATION 9 9 AUTOMATICS 10 10 DEVICE COMMISSIONING 11 11 REPAIRS MAINTENANCE AND DECOMMISSIONING 12 12 TROUBLESHOOTING 12 13 INFORMATION 12 ...

Страница 5: ...ating and ventilation unit AGE Size 1 2 3 4 5 6 Heater power 3 6 9 12 18 27 36 kW 3 DEVICE DESCRIPTION AGE unit series include 6 sizes Fig 1 The unit features axial fan 1 heating system 2 heating elements with rolled aluminium radiator in a self clamping sieve Leads of connected heaters with rigid bridges and cables included with the control elements I II and III row heating systems available cont...

Страница 6: ...GE 5 18 502 515 325 160 400 27 18 2100 1400 120 230 28 AGE 6 27 502 575 375 180 400 39 27 2900 1400 200 230 34 Lmin minimum unit distance from the wall Units are fitted with 10 mm high feets Unit thermal power and air temperature increase Table II Unit size Heater stage I II III P kW Dt O C P kW Dt O C P kW Dt O C AGE 1 3 3 19 AGE 2 6 3 10 6 21 AGE 3 9 6 12 9 18 AGE 4 12 6 12 9 18 12 24 AGE 5 18 6...

Страница 7: ...s connected to the electrical system with residual device and protective terminal earth The thermostat preventing overheating must be connected in the heating unit control system Do not switch on the unit without the fan running Potential free state is obtained by disconnecting the power supply cable from the socket Due to its design the device does not emit any hazardous radiation Important note ...

Страница 8: ...al columns in the distance between the unit and the fan air inlet equal to 0 5x fan diameter Lmin Table I Fig 2 and 3 shows layout and functions of control elements b a c AGE 1 3 Fig 2 Layout and functions of control elements a control button Fan I on O off a control button O heating unit off position 1 or 2 heating stage selection c button red maximum heating element temperature threshold alarm r...

Страница 9: ...nnecting switch distance between the contacts of all poles 3 mm directly by the unit The cross sections of power cable depend on the unit power and terminal types in accordance with power supplier requirements Power cable is terminated with a plug for sockets with earth pin Connect the unit in accordance with the wiring diagrams in the operation and installation manual Fig 4 and 5 show example wir...

Страница 10: ...itted with a THERMOSTAT of the heater element limiting and monitoring outlet air temperature in case of air flow disturbances e g fan failure Thermostat temperature setting range is 0O C to 100O C with constant hysteresis of 3O C Monitoring temperature is factory set at 80O C and limit temperature is always higher by 20ºC than the preset temperature Jako dodatkowa opcja aparaty mogą być wyposażone...

Страница 11: ... b to 0 press a fan ON press b to switch on the heating unit button will light After use press b to switch off the heater press a to switch off the unit The fan will continue to rotate for 15 20 seconds The unit will switch off automatically after the heater element temperature is reduced In case of voltage decay or other interferences press c restart the unit AGE 4 AGE 5 AGE 6 units Before start ...

Страница 12: ...partment or a qualified fitter Description of malfunction Possible causes of malfunction Measures of prevention removal excessive unit no ise incorrect distance from wall or ceiling maintain required distance incorrect power supply parameters use with correct mains and device parameters air outlet limited with outlet grille shutters keep the outlet grille shutters open at high speed obro towej wen...

Страница 13: ...l damages and aleatory damages or damages caused by the atmospheric factors b damages occurred as a result of non observance of typical rules or the rules required by the instruction manual related to the operation and mounting of the unit or the use of the unit against the intended use and other damages caused by the Customer s activity or omission c damages being a result of defective operation ...

Страница 14: ...mp name and signature Motor current A User s representative stamp name and signature Remarks V INSPECTION AND MAINTENANCE DOCUMENT Date of inspection Executor of inspection stamp name and signature Service activity range Remarks Inspection of the unit in accordance with the section Repair and Maintenance in the instruction manual ...

Страница 15: ...ry No Year of production Startup executed by Description of defect NOTE AFTER COPYING AND FILLING IN SEND THE NOTIFICATION BY FAX OR EMAIL TOGETHER WITH A COPY OF THE STARTUP REPORT JUWENT Company accepts notifications filled legibly and completely When the lodged claim is not justified the claimer will be burdened with service costs Date of warranty issue Order No company s stamp ...

Отзывы: