background image

Introduction

 

Thank you for choosing a JUWEL Aquarium product.

 

 

Our products represent over 40 years experience in the manufacturing of aquariums
and their acessories applying most modern production techniques bringing together
the JUWEL Aquarium system, which is both easy to use and simple to maintain.

Important:

Please read this instruction manual carefully and completely to make sure you
have received all components before setting up the aquarium.

 

 

Please observe the safety instructions and maintenance guidelines given in this
manual.

 

 

This instruction manual has been carefully prepared to provide you with accurate
and complete information. All efforts have been made to ensure that the
information given is correct. However, we cannot accept responsibility for
printing or other errors. Technical details are always approximate and are not
warranted characteristics and may be subject to change without notice.

 

 

Always unplug all immersed electrical equipment from mains before placing your
hands into the water.

Important:

The use of additional air stones or air lines is not necessary with the JUWEL
Aquariums. If an air stone is used, this should always be placed in the middle of
the aquarium. Capillary leaks resulting from the use of these items will not be
accepted as a fault with the aquarium.

 

 

Do not transport or move your aquarium while still containing water or sand.

 

 

Always take care not to damage the seals while maintaining your aquarium.

 

 

Do not use toxic substances to clean your aquarium.

Safety instructions:

This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of
the appliance in a safe way and understand the hazards involved. Children shall
not play with the appliance. Cleaning and user maintenance shall not be made by
children without supervision.

Operation with the RC circuit breaker only, max. 30mA.

The power plugs of the electrical devices must not become moist. Connect the
power plugs to the power supply at such a height that the connection cable
forms a loop which would enable the water to drip down.

2

Содержание Rio 240

Страница 1: ...Instruction Manual Rio 240 www juwel aquarium com ...

Страница 2: ... the water Important The use of additional air stones or air lines is not necessary with the JUWEL Aquariums If an air stone is used this should always be placed in the middle of the aquarium Capillary leaks resulting from the use of these items will not be accepted as a fault with the aquarium Do not transport or move your aquarium while still containing water or sand Always take care not to dama...

Страница 3: ...e been made to match the dimensions and to bear the weight of the filled aquarium The cabinet must be positioned on a level surface The JUWEL Aquarium is built with a special bottom frame for security The aquarium should be placed directly onto the cabinet DO NOT place any additional support e g polystyrene under the aquarium since this is not necessary with our aquariums Weight of the aquarium in...

Страница 4: ...e couplings intake tubes etc The capacity of the pump is designed in such a manner that an ideal level of biological filtering is ensured by a sufficient level of percolation through the filter material In that context the large filter volume ensures excellent mechanical filtering and facilitates long cleaning intervals The construction of the filter system enables you to quickly access the indivi...

Страница 5: ...r 5 Now start preparing the filter sponges by removing the plastic packaging from the carbon sponge and the nitrate remover sponge and the Cirax filter medium Thoroughly rinse the blue filter sponges only under running water 6 After this insert the blue fine filter sponges and the Cirax filter medium into the lower filter basket Following that place the blue rough filter sponge the green nitrate r...

Страница 6: ... organisms in the filtration system it is recommended to exchange the sponge every 6 weeks The nitrate removal sponge contains bacteria which will after a while reduce the nitrate level in the aquarium significantly Important Always use original JUWEL Aquarium filter media to ensure the optimum performance of your system Maintenance of the pump JUWEL Eccoflow in the filter system Bioflow Super 3 0...

Страница 7: ...ntly in the water stream facilitates even warming of the water in the aquarium You control the temperature of the water via the adjusting knob in the heater head You may specify the temperature the heater is supposed to heat the water to in accordance with your individual requirements The centre position between and corresponds to a water temperature of approximately 23 26 degrees Celsius or 74 78...

Страница 8: ...em The water tightness can only be guaranteed if the tube holders have been firmly connected to their sockets We recommend that you check this prior to connecting the lighting unit to the power supply The light unit can now be placed onto the top frame and can be connected to the power supply Having done this please fit the flaps to close the aquarium completely Notice The JUWEL fluorescent tubes ...

Страница 9: ...Caps To ensure the water tightness of your Multilux light system always use genuine JUWEL Aquarium spare parts Please note the tube holders are available from your JUWEL Aquarium retailer In the event of a problem the Multilux light system will automatically switch off If after replacing both light tubes the unit still fails to work then the unit itself will need replacing Please see your aquarium...

Страница 10: ...repayment of the purchase price 2 Guarantee period and settlement procedure 1 The guarantee period begins on the day of the purchase of the product from the retailer Claims under this guarantee will not be honoured if a the damage is caused as a result of improper use or maintenance or non observance of the instructions given in this manual b the product or its components have been maintained by p...

Страница 11: ...240 MULTILUX SB 121 Artikel Bestell Nr 2teilig 2 piece 93915 ersetzen 46420 47820 only GB 46720 only AU 92003 86354 High Lite Day 86454 High Lite Nature 86554 High Lite Colour 86654 High Lite Marine 86754 High Lite Blue ...

Страница 12: ...JUWEL FILTER SYSTEM Bioflow 3 0_Juwel Eccoflow_200W Artikel Bestell Nr 85093 85754 85764 only GB 85774 only AU 85610 85810 only GB 85860 only AU 90046 88049 88059 88055 88050 88051 88056 88057 ...

Отзывы: