background image

Maintaining the JUWEL Pump Bioflow 

 

The JUWEL aquarium pump requires little maintenance. Regardless, you should confirm
the functionality at regular intervals.

 

 

Please perform the following steps in order to test and maintain the pump:

 

 

1. Disconnect the pump and the heater from the power supply.

 

 

2. Remove the nozzles.

 

 

3. Remove the pump from the pump holder of the filter.

 

 

4. Remove the pump housing from the motor and remove the impeller.

 

 

5. Thoroughly clean all parts and particularly check the impeller for signs of wear at
the magnet. 

 

 

6. After that, please reinstall the pump in reverse order in the filter.

 

 

BIOFLOW SUPER

D_6_60_Bild

 

Recommendation:

In order to ensure that the power head operates at its optimum and maintains its
low noise level, we recommend to check and potentially replace the parts subject
to wear and tear, such as the impeller regularly.

 

 

All spare parts are available from your local JUWEL Aquarium retailer.

Safety instructions:

Never operate the power head out of water.

 

 

Always unplug the power head from the power supply before removing it from the
filter.

 

 

The power head is intended for indoor use and for use in fluids up to 35°C.

 

 

Never repair the electrical cord or plug. In case of damage replace the complete
power head.

The cover light system JUWEL Violux

 

You achieve the optimum lighting for your aquarium with the cover light by JUWEL
Aquarium, and it simultaneously offers you access to the aquarium for maintenance
measures while being lit. 

 

 

The light itself is waterproof; because of that, cover panes against slash water which
would reduce the luminosity are not required. 

 

 

 

 

The cover light by JUWEL Aquarium consists of 

 

 

- Covering hood (1) 

 

 

- Compact fluorescent lamp JUWEL Twin-Lite PL4 (15 watts) (2) 

 

 

- Service hatch (3) for the supply of feed and water treatment agents etc.

 

 

Violux_40_PL_Detail

Violux_40_Montage_2

Violux_40_PL_GBW

Vio40_Aufstellen

Violux_40_Detail_Scharnier_Rahmen

3

2

1

Safety instructions:

Do not operate the light under water.

 

 

Do not attempt to open the light or repair it in case of a malfunction! This would
endanger the waterproofness.

 

 

Install the JUWEL Twin-Lite PL Light unit only in aquarium hoods made by JUWEL
Aquarium from polystyren or ABS to fit the safety requirements using the
specially constructed holders.

Safety instructions:

Pull the power plug for each light replacement.

 

 

The connection line may not be repaired. Always replace the entire light in case
of damage.

 

 

For Replacement use only original JUWEL Twin-Lite PL Light units!

5

Содержание VIO 40

Страница 1: ...Instruction Manual VIO 40 www juwel aquarium com...

Страница 2: ...ore placing your hands into the water Important The use of additional air stones or air lines is not necessary with the JUWEL Aquariums If an air stone is used this should always be placed in the midd...

Страница 3: ...in the chapter Putting the JUWEL filter Bioflow Mini into operation 3 Complete the decoration with ground material etc as desired 4 Plant the short plant species in the aquarium if applicable 5 Slowly...

Страница 4: ...oflow_Mini_spreng Compact_fein_bunt The JUWEL Aquarium Filter System is a biological filter system For it to work effectively bacteria cultures will need to grow inside the blue sponges This process c...

Страница 5: ...fluids up to 35 C Never repair the electrical cord or plug In case of damage replace the complete power head The cover light system JUWEL Violux You achieve the optimum lighting for your aquarium with...

Страница 6: ...each fluorescent lamp loses luminosity in the course of time Of course this affects the growth of the plants in your aquarium Because of that we recommend you to replace the compact fluorescent lamp...

Страница 7: ...tioned arrangement 2 It is the prerogative of JUWEL Aquarium to decide whether the guarantee is performed by means of repair or replacement If neither repair nor replacement can ensure the performance...

Страница 8: ...Aquarien Pass VIO 40 VIOLUX 40 Aquarium Pass VIO 40 VIOLUX 40 Artikel Bestell Nr 86100 86102 only GB 86103 only AU...

Страница 9: ...JUWEL FILTER BIOFLOW MINI Artikel Bestell Nr 280 400 600 1000 1500 1500 Bioflow 85070 Bioflow 1500 Bioflow 280 400 600 1000 85720 85730 only GB 85740 only AU 88051...

Отзывы: