Justec OxiEasy W60 Скачать руководство пользователя страница 4

    

Justec Shenzhen CO., LTD.

 

                       

                                                                        Version:2.0 

 

 OxiEasy W60 User Manual                                                                                                                                                               4 

2.Parts Instruction 

2.1  Components Description 
                                                    

                                                                                

8

9

 

 

                                                                      

 

 

                                                                                   

 

 
 

1. Watch strap 

5.Power button /Confirm button 

9. Fingertip sensor 

2. Sensor  port 

6. Lock screen key /Down button 

10. probe 

3. Display 

7. Clasp 

11. Indicator light 

4. Menu key /Up button 

8. Sensor  connector 

12. USB connector 

 

2.2 Display each icon description 
 

No. 

Symbols/Indicators 

Definition 

 

Indication of  low battery level. The icon will flash and turn 
red if the battery is low. 

Low  Bat

 

Low voltage alarm 

9 8

S pO 2%

 

The SpO2 value shows the blood oxygen saturation level 
expressed as a percentage. The small number shown 
immediately  above and below the measured value on the right 
side indicate the upper and lower alarm limits. 

7 5

P R b p m

 

Pulse  rate  in beats per minute. 

 

The  bar graph is an indicator for signal quality. 

 

Poor signal 

 

Pulse waveform ( plethysmogram ) The reading is 
automatically adjusted to the pulse strength; therefore, a 
waveform with strong amplitude should be visible at all times. 

 

Bluetooth figure mark. 

Содержание OxiEasy W60

Страница 1: ...JT OxiEW60 UM01 OxiEasy W60 Pulse Oximeter User Manual Easy Reliable and Smart...

Страница 2: ...rnings 3 2 Parts Instruction 4 3 Operation instructions 5 4 Screen off Device 5 5 Erro Messages Problems Corrective Actions 6 6 Battery and Charger 7 7 Maintenance Cleaning 7 8 Specification 8 9 Testi...

Страница 3: ...lid reading of the W60 Failure to cover the sensor site with opaque material in high ambiernt light conditions may result in inaccurate measurement Disconnect the OxiEasy W60 and sensor from the patie...

Страница 4: ...ry level The icon will flash and turn red if the battery is low 2 Low Bat Low voltage alarm 3 98 SpO 2 The SpO2 value shows the blood oxygen saturation level expressed as a percentage The small number...

Страница 5: ...o to turn on or turn off the transmission 2 Date and time 4 Screen of Device 4 1 Main Menu All important and frequently used setting are accessible through the main menu which can be opened by pressin...

Страница 6: ...ly attached to the patient Low battery battery symbol blinking red The battery is almost completely discharged Replace batteries immediately Sensor fault The connected sensor is either defective or no...

Страница 7: ...lular phones Mobile two way radios Electrical appliances High definition televisions HDTV s The monitor is designed for use in environments in which the pulse can be obscured by electromagnetic interf...

Страница 8: ...nes whether the oximeter meets the criteria of ISO 80601 2 61 for pulse rate during simulated movement tremor and spike motions 10 Warranty We give 1 year warranty for defects caused by material or ma...

Страница 9: ...cement Parts 12 1 Packing List OxiEasy W60 main unit Sensor USB Connector CD 12 2 Main Accessories Description Main unit USB Connector Sensor Model Manufacturers Structure S18 S8137 Himed S16 S7137 Hi...

Страница 10: ...60 User Manual 10 JUSTEC Justec Shenzhen CO LTD Add Room 2018 2nd Floor 64th Building Jinlong Industrial Area Qilin Road Nanshan District 518052 Shenzhen People s Republic of China Tel 0086 755 260689...

Отзывы: