background image

Please take the following in account before using the NSK E-TYPE handpiece;

 

• To connect the motor and the handpiece, 

align the positioning marks of the motor and 
the handpiece, and insert straightly. To 
disconnect, hold the front part of the motor 
and the back part of the handpiece, and pull 
out straightly. Do not connect or disconnect 
the handpiece until the motor has 
completely stopped. 

• To mount the bur, insert it into the chuck 

and turn the Bur Lock Ring in the direction 
of the mark [C] until it clicks and the Black 
Dots align (*See the picture below). To 
remove the bur, turn the Bur Lock Ring in the 
direction of mark [O] until it clicks. Most 
common mistake is that people start working 
in the middle position, between the lock and 
unlock. Never do that! 

• Never use bent, off-centered or damaged burs. Excessive loads generated by defective burs 

will quickly damage ball bearings. 

• This handpiece is designed for (dental) treatment and precision technical use. Longtime 
excavation with high torque with thick burs such as 2,8mm up may cause a short life to the 
handpiece chuck. 
• Always insert a bur all the way into chuck. This will prevent “BUR- WALK-OUT”, and/or 
damage to the ball bearing. 
• Never operate Straight Nosecone without a bur or bur blank securely in place, or bur lock 
ring at different positions. 

• Make sure if the Os of the bur lock ring line up after fixing the bur. Rotating the bur in an 
improper position may cause heat generation, which results in burns 

JURA Engraving system:  

What makes the JURA Artgraver special beyond the air compressor free feature?  It's the 
handpiece. The single handpiece can be quickly modified by switching out the piston to 
allow for a wide variety of engraving styles from light bulino work to heavy engraving in 
hard metals like steel and titanium.  

Отзывы: