background image

1.  Read all instructions.

2.  Do not conceal or extend bus bar con-

ductors (Flex 12 Trac) through a building 

wall.

3.  Do not install this system in damp or wet 

locations.

4.  To reduce the risk of fire and burns, do 

not install this lighting system where the 

uninsulated open bus bar conductors 

can be shorted or contact any conduc-

tive materials.

5.  Do not install any luminaire closer than 

6 inches (15.25 cm) from any curtain, or 

similar combustible material.

6.  To reduce the risk of fire and overheat-

ing, make sure all connections are tight.

7.  Turn off electrical power before installing 

or modifying the system in any way.

8.  Use 10 or 12 gauge wire to connect the 

output to the Trac.

9.  These transformers are intended for use 

with Juno Flex 12 Series or Trac 12/25 

Series low voltage lighting systems only.

PARTS LIST
Open the carton and identify all of the fol-
lowing parts: 
(1)  Chassis / transformer assembly 

(A)

(1) 

Cover 

   (C)

(1) 

Knob 

   (K)

(1)  Parts bag including:
     (1) 

Mounting strap 

 

(B)

     (1) 

Grommet  

 

(G)

     (2) 

Nuts, 1/8 inch 

 

(N)

     (1) 

Nipple, 1/8 x 2 3/4 inch 

(Q)

     (1) 

Ground screw 

 

(S)

     (2) 

Wire nuts

PRODUCT FEATURES
Juno’s surface mounted power units are 

used to convert 120 volts AC to 12 volts 

nominal to provide power to the Flex 12 

trac. The Trac length should not exceed 24 

feet in either direction from the feed. The 

power units are designed to be mounted 

to a standard ceiling mounted junction box 

that is adequately supported. They can 

be used with one or two Pendants, or with 

the Flexible Feed (Pendants and Flexible 

Feed sold separately). The power units are 

capable of supporting up to 20 lbs. They 

should not be mounted in any location that 

may entrap heat.

The TF6150E is capable of operating from 

50 to 150 watts of lamp load and is dim-

mable with most higher quality incandescent 

dimmers. In some cases, dimmers designed 

for electronic transformers may be neces-

sary for optimal dimming results. The unit 

has short circuit and overload protection that 

will automatically reset itself when the short 

or overload is removed. 

The TF6300 is capable of operating from 

150 to 300 watts of lamp load and is dim-

mable only with dimmers specifically 

designed for magnetic transformers. To 

protect against an overload or short circuit, 

the unit contains a circuit breaker that must 

be manually reset after the short or overload 

has been removed.

INSTALLATION
WARNING:  Make sure power is off 

before assembly
1.
  Make sure that the supply wires protrude 

from the junction box at least 7 inches.

2.  Thread the nipple (Q) through the nut 

(N) and strap (B) with the tapered side 

away from the nut as shown. Attach the 

ground screw (S) to the strap.

3.  Pass the supply wires from the junction 

box through the nipple as shown. Secure 

the strap to the junction box with two 

screws. Connect the ground wire from 

the junction box to the ground screw on 

the strap.

4.  Adjust the nipple to protrude 2 inches 

from the mounting surface and lock in 

place with the nut.

5.  (TF6300 only) Loosen the two wing nuts 

(W) on the center mounting bracket (M) 

of the transformer assembly and rotate 

the bracket out of the way.

6.  Pass the supply wires and the nipple 

through the center of the assembly (A). 

Raise the assembly to the mounting 

surface. Place the remaining nut over 

the supply wires and thread it onto the 

nipple to hold the assembly in place.

7.  Rotate the assembly if necessary to ori-

ent the pendant(s) as desired, and finish 

tightening the nut to secure the assem-

bly in place.

8.  Connect the white and black supply 

wires to the stranded input wires from 

the assembly with the wire nuts pro-

vided. 

9.  (TF6300 only) Carefully bend the supply 

wires to the side, rotate the top bracket 

back in place, and tighten the wing nuts. 

10. Install the Pendant Feed or Flexible 

Feed per the appropriate instructions on 

the following page.

----- See steps 11-15 on back. -----

16. Connect the feed wires to the terminal 

block (TB). CAUTION: For all connec-

tions, make sure that the stripped wire 

is fully inserted into the connector, all 

strands of copper are inserted in the ter-

minal and all 4 screws are tight.

17. Connect the green ground wire from the 

assembly to the tab (T) on the inside of 

the cover (C).

18. (TF6300 only) Make sure that the circuit 

breaker switch (CB) located on the side 

of the assembly, is on.

19. Put the cover in place and secure it to 

the assembly with the knob (K). Install 

the Trac and fixtures per the instructions 

included with them.

20. Apply AC power. Confirm that all fixtures 

function acceptably. Adjust fixtures as 

desired.

IMPORTANT SAFEGUARDS:

When using electrical equipment, always adhere to basic safety precautions including the following:

IMPORTANT SAFETY/ OPERATING INSTRUCTIONS

Surface Mount Power Units

TF6150E 12 volt, 150 watt, single output

TF6300 12 volt, 300 watt, single output

SAVE THESE INSTRUCTIONS

pg 1 of 3

INSTALLATION INSTRUCTIONS