JUNO JKI 2438 Скачать руководство пользователя страница 8

18

Installation

Take utmost care when handling your
appliance so as not to cause any damages to
the cooling unit with consequent possible fluid
leakages.

¥ During normal operation, the condenser and

compressor at the back of the appliance heat up
considerably. Always ensure that there is adequate
ventilation as a failure to do this will result in
component failure and possible food loss. See
installation instructions.

¥

Important:

if the supply cord is damaged, it must

be replaced by a special cord or assembly availa-
ble from the manufacturer or its service agent.

Positioning

¥ Unpack the cabinet and check that it is in good

condition and free of any transport damage.

¥ Place the refrigerator away from direct sunlight and

heat sources.

¥ Avoid prolonged exposure of the appliance to

direct sunlight.

¥ For safety reasons, minimum ventilation must be

as shown in Fig.

Attention: keep ventilation openings clear of
obstruction.

¥ It is necessary that the niche is provided with a

conduct of venti-lation having the following
dimensions:
Depth 50 mm
Width 540 mm

The climate classification can be found on the rating
plate, which is located inside the cabinet on the left
hand wall.

The following table shows which ambient
temperature is correct for each climate classification:

Climate
classification

SN

+10 to +32¡C

+16 to +32¡C

+18 to +38¡C

+18 to +43¡C

N

ST

T

for an ambient temperature of

50 mm

min.
200 cm

2

200 cm

2

min.

D526

When the ambient temperature is not included
within the range indicated for the class of this
appliance, the storage temperature in the
appliance cannot be guaranteed; therefore it is
advisable to use the food stored as soon as
possible.

Electrical connection

Before plugging in, ensure that the voltage and
frequency shown on the serial number plate
correspond to your domestic power supply.
Voltage can vary by ±6% of the rated voltage.
For operation with different voltages, a suitably sized
auto-transformer must be used.

Important
The appliance must be earthed.

The power supply cable plug is provided with a
contact for this purpose.

If the domestic power supply socket is not
earthed. connect the appliance to a separate
earth in compliance with current regulations,
consulting a specialist technician.

The Manufacturer declines all
responsibility if the above safety
precautions are not observed.

This appliance complies with the following E.E.C.
Directives:

- 87/308 EEC of 2/6/87 relative to radio

interference suppression.

- 73/23 EEC of 19.2.73 (Low Voltage
Directive)  

and subsequent modifications.

- 89/336 EEC of 3.5.89 (Electromagnetic 

Compatibility Directive) and subsequent 
modifications.

Attention!

It must be possible to disconnect the appliance

from the mains power supply; the plug must
therefore be easily accessible after installation.

Содержание JKI 2438

Страница 1: ...2222745 02 GEBRAUCHSANWEISUNG OPERATING INSTRUCTION D t JKI 2438 JKI 4438 JKI 4468...

Страница 2: ...the cabinet and always use gloves Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person Ensure that the appliance does not stand o...

Страница 3: ...yethylene PS polystyrene PP polypropylene All materials are environmentally sound Disposal of old Appliances Information concerning collection schedules or locations can be obtained from your local Co...

Страница 4: ...ill enter the cabinet and cause the compressor to switch on unnecessarily often If the ambient temperature is high the thermostat knob is on the coldest setting higher numbers and the appliance is ful...

Страница 5: ...f the storage time Be sure that frozen foodstuffs are transferred from the foodstore to the freezer in the shortest possible time Do not put carbonated liquids fizzy drinks etc in the freezing compart...

Страница 6: ...as follows Remove any stored food wrap it in several layers of newspaper and put it in a cool place Pull out the plug from the wall socket or turn the thermostat knob to the O setting Leave the door...

Страница 7: ...unobstructed The cause could be the introduction of large quantities of food and or frequent opening closing of the door Sometimes is normal During automatic defrosting frost thaws on the cooling plat...

Страница 8: ...classification SN 10 to 32 C 16 to 32 C 18 to 38 C 18 to 43 C N ST T for an ambient temperature of 50 mm min 200cm2 200 cm 2 min D526 When the ambient temperature is not included within the range ind...

Страница 9: ...rding to the door opening direction remove relevant pins at the top and at the bottom Warning If the ambient temperature is cold i e in Winter the gasket may not fit perfectly to the cabinet In that c...

Страница 10: ...of the recess JKI 2438 JKI 4438 JKI 4468 Height of housing 1 880 1225 mm Depth of housing 2 550 550 mm Width of housing 3 560 560 mm It is necessary that the niche is provided with a conduct of ventil...

Страница 11: ...into guide A Put together the appliance door and the furniture door and mark the holes as indicated in the figure Remove the squares and drill holes with 2 mm at 8 mm from the outer edge of the door P...

Страница 12: ......

Страница 13: ......

Страница 14: ...923692691 923692692 923458608...

Отзывы: