A3
IS FLASHING
Flue gas NTC is blocked
Control
S
tep
Order
Measure
1.
Yes:
Change flue gas NTC.
If A3 still flashing?
↓
2.
No:
2.
Electronic card is out of order.
Yes:
?
Pull out connections of flue gas NTC
?
Measure the resistance
Is the range in between 0-30 k?
Switch off the appliance
Cut mains supply
Change the electronic card.
Connect to mains supply
Switch on the appliance
Check cable connectýons(especially on RAS5;20
way connector) ýf needed replace cable harners