Table 53: Airflow Direction in AC Power Supply Models for EX4300 Switches
Direction of Airflow
Label on Power
Supply
Model
Front-to-back—that is, air intake to cool the chassis is through the
vents on the front panel of the chassis and hot air exhausts through
the vents on the rear panel of the chassis.
AIR OUT (AFO)
JPSU-350-AC-AFO-A
Back-to-front—that is, air intake to cool the chassis is through the
vents on the rear panel of the chassis and hot air exhausts through
the vents on the front panel of the chassis.
AIR IN (AFI)
JPSU-350-AC-AFI-A
Front-to-back—that is, air intake to cool the chassis is through the
vents on the front panel of the chassis and hot air exhausts through
the vents on the rear panel of the chassis.
AIR OUT (AFO)
JPSU-715-AC-AFO-A
Front-to-back—that is, air intake to cool the chassis is through the
vents on the front panel of the chassis and hot air exhausts through
the vents on the rear panel of the chassis.
AIR OUT (AFO)
JPSU-1100-AC-AFO-A
Front-to-back—that is, air intake to cool the chassis is through the
vents on the front panel of the chassis and hot air exhausts through
the vents on the rear panel of the chassis.
AIR OUT (AFO)
JPSU-1400W-AC-AFO
N+0 Redundancy Configuration of AC Power Supplies
In an N+0 redundancy configuration, lower priority PoE ports may be impacted if a power supply fails.
lists the N+0 power calculation for 24-port EX4300 switches that use 350 W, 715 W,
and 1100 W power supplies.
Table 54: N+0 AC Power Calculations for 24-Port EX4300 Switches
Ports
Enabled
for
PoE+
Available
PoE
Power (in
watts)
Base
Power (in
watts)
Backup
Power
(in
watts)
Usable
System
Power (in
watts)
Total
Power (in
watts)
PSU
0
(W) +
PSU
1
(W)
Power Supply Rating
PSU
1
PSU
0
6
200
150
0
350
350
–
350 W AC
17
515
150
0
665
700
350 W AC
350 W AC
174
Содержание QFX3500
Страница 1: ...Virtual Chassis Fabric Hardware Documentation Published 2020 11 06...
Страница 225: ...Translation The emitted sound pressure is below 70 dB A per EN ISO 7779 201...
Страница 229: ...205...
Страница 238: ...Unterminated Fiber Optic Cable Warning 214...
Страница 246: ...Restricted Access Warning 222...
Страница 249: ...225...
Страница 257: ...Jewelry Removal Warning 233...
Страница 260: ...Operating Temperature Warning 236...
Страница 271: ...DC Power Disconnection Warning 247...
Страница 275: ...DC Power Wiring Sequence Warning 251...
Страница 278: ...DC Power Wiring Terminations Warning 254...
Страница 408: ...Understanding Virtual Chassis Fabric Configuration 4 Understanding Virtual Chassis Fabric Components 384...
Страница 410: ...Figure 130 All QFX5110 VCF g050760 Figure 131 QFX5110 VCF with QFX5100 24Q Leaf Devices 386...
Страница 412: ...Figure 132 QFX5100 24Q as a Leaf Device in a QFX5110 VCF 388...
Страница 565: ...Table 105 System Information continued Description Field Inventory details 541...
Страница 602: ...6 PART Troubleshooting Restoring Junos OS 579 Returning Hardware 586 Alarms and System Log Messages 623...