background image

SRX210 Services Gateway Quick Start

Use the instructions in this quick start to help you connect the SRX210 Services 
Gateway to your network. For details, see the 

SRX210 Services Gateway Hardware 

Guide

 at http://www.juniper.net/techpubs/a057.html .

SRX210 Services Gateway Front Panel

SRX210 Services Gateway Back Panel

SRX210 Services Gateway Models

The following models of SRX210 Services Gateways are available:

On the SRX210H-POE, SRX210HE-POE and SRX210HE-POE-TAA models, Power 
over Ethernet (PoE) of 50 watts is supported across four ports (

0/0

0/1

0/2

, and 

0/3

).

Note that you must use the following power supply adapters (supplied) for your services 
gateway:

„

54V, 150 watts power supply adapters for PoE models

„

12V, 60 watts power supply adapters for non-PoE models

Connecting and Configuring the SRX Series Device

Follow the instructions to connect and set up the SRX210 Services Gateway to protect 
your network. Refer to the LEDs on the front of the device to help you determine the 
status of the device.

Overview

The SRX210 Services Gateway is a security device that requires the following basic 
configuration settings to function:

„

Interfaces must be assigned IP addresses.

„

Interfaces must be bound to zones.

„

Policies must be configured between zones to permit or deny traffic.

„

Source NAT rules must be set.

The device has the following default configuration set when you power it on for the first 
time. To use the device, you do not need to perform any initial configuration.

Callout Description

Callout Description

1

Mini-PIM slot

5

USB ports

2

Power button

6

Console port

3

LEDs (ALARM, POWER, 
STATUS, HA, mPIM, EXPCARD)

7

Gigabit Ethernet (0/0 and 0/1) and Fast 
Ethernet (0/2 to 0/7) ports

4

Reset Config button

Callout Description

Callout Description

1

Power supply input

4

Lock for security cable

2

Cable tie holder

5

ExpressCard slot

3

Grounding point

g031

132

g031

1

1

3

Device

DDR Memory

Power over 

Ethernet

SRX210B

512 MB

No

SRX210H

1 GB

No

SRX210H-POE

1 GB

Yes

SRX210BE

512 MB

No

SRX210HE

1 GB

No

SRX210HE-POE

1 GB

Yes

SRX210HE-TAA

1 GB

No

SRX210HE-POE-TAA

1 GB

Yes

Содержание PowerConnect J-SRX210

Страница 1: ...n the front of the device to help you determine the status of the device Overview The SRX210 Services Gateway is a security device that requires the following basic configuration settings to function Interfaces must be assigned IP addresses Interfaces must be bound to zones Policies must be configured between zones to permit or deny traffic Source NAT rules must be set The device has the following...

Страница 2: ...the supplied DB 9 adapter which then connects to the serial port on the management device serial port settings 9600 8 N 1 If you are using this method to connect proceed with the CLI configuration instructions in the Branch SRX Series Services Gateways Golden Configurations at http www juniper net us en local pdf app notes 3500153 en pdf An illustration to connect a management interface Task 3 Ens...

Страница 3: ...s settings are optional If you have followed method 1 of Task 4 Obtaining a Dynamic IP Address on Your Services Gateway you can skip all the other steps and go directly to Task 7 If you have followed method 2 of Task 4 Obtaining a Static IP Address on Your Services Gateway ensure that you make the following J Web modifications 1 On the Configure System Network Settings page of the wizard enter the...

Страница 4: ...y shuts down Press the Power button again to power on the device You can reboot or halt the system in the J Web interface by selecting Maintain Reboot NOTE Use the graceful shutdown method to halt power off or reboot the services gateway Use the forced shutdown method as a last resort to recover the services gateway if the services gateway operating system is not responding to the graceful shutdow...

Отзывы: