background image

Juniper Networks, Junos, Steel-Belted Radius, NetScreen, and ScreenOS are registered trademarks of Juniper Networks, Inc. in the United States and other countries. The Juniper Networks Logo, the Junos logo, and JunosE are 
trademarks of Juniper Networks, Inc. All other trademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners. Juniper Networks assumes no responsibility for any inaccuracies 
in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice. Products made or sold by Juniper Networks or components thereof might be covered by one or more 
of the following patents that are owned by or licensed to Juniper Networks: U.S. Patent Nos. 5,473,599, 5,905,725, 5,909,440, 6,192,051, 6,333,650, 6,359,479, 6,406,312, 6,429,706, 6,459,579, 6,493,347, 6,538,518, 6,538,899, 
6,552,918, 6,567,902, 6,578,186, and 6,590,785. Copyright © 2011, Juniper Networks, Inc. All rights reserved. Printed in USA. Part Number: 530-038122 Rev. 01, March 2011.

After you complete initial setup configuration, the Setup wizard is no longer available. To 
make changes to the configuration, use the J-Web interface. 

NOTE: 

To make any changes to the interface configuration, see the 

Branch SRX Series 

Services Gateways Golden Configurations

 at 

http://www.juniper.net/us/en/local/pdf/app-notes/3500153-en.pdf .

Task 8: Verify the Configuration

Access http://www.juniper.net to ensure that you are connected to the Internet. This 
connectivity ensures that you can pass traffic through the services gateway. 

NOTE: 

If the http://www.juniper.net page does not load, verify your configuration settings, 

and ensure that you have applied the configuration.

After you complete these steps, you can pass traffic from any trust port to the untrust 
port.

Powering Off the Device

You can power off the device in one of the following ways:

„

Graceful shutdown—Press and immediately release the Power button. The device 

begins gracefully shutting down the operating system. 

„

Forced shutdown—Press the Power button, and hold it for 10 seconds. The device 

immediately shuts down. Press the Power button again to power on the device.

You can reboot or halt the system in the J-Web interface by selecting 

Maintain > 

Reboot

.

NOTE: 

Use the graceful shutdown method to halt, power off, or reboot the services 

gateway. Use the forced shutdown method as a last resort to recover the services 

gateway if the services gateway operating system is not responding to the graceful 

shutdown method.

For additional configuration information, see the 

Branch SRX Series Services Gateways 

Golden Configurations 

at 

http://www.juniper.net/us/en/local/pdf/app-notes/3500153-en.pdf .

For detailed software configuration information, see the software documentation 
available at http://www.juniper.net/techpubs/software/junos-srx/index.html .

Using the Reset Config Button

If a configuration fails or denies management access to the services gateway, you can 
use the Reset Config button to restore the device to the factory default configuration or to 
a rescue configuration. For example, if someone inadvertently commits a configuration 
that denies management access to the services gateway, you can delete the invalid 
configuration and replace it with a rescue configuration by pressing the Reset Config 
button.

NOTE: 

The Reset Config button is recessed to prevent it from being pressed 

accidentally.

The rescue configuration is a previously committed, valid configuration. You must have 
previously set the rescue configuration through the J-Web interface or the CLI.

To press the Reset Config button, insert a small probe (such as a straightened paper clip) 
into the pinhole on the front panel.

„

By default, pressing and quickly releasing the Reset Config button loads and 

commits the rescue configuration through the J-Web interface or the CLI. The Status 

LED is amber and steadily on during this time. 

„

By default, pressing and holding the Reset Config button for 15 seconds or 

more--until the Status LED is amber and steadily on--deletes all configurations on 

the device, including the backup configurations and rescue configuration, and loads 

and commits the factory configuration.

For details about managing and monitoring your device, see the 

Junos OS 

Administration Guide

 and the 

Junos OS CLI Reference Guide

.

Contacting Juniper Networks

For technical support, see http://www.juniper.net/support/requesting-support.html .

Содержание PowerConnect J-SRX210

Страница 1: ...n the front of the device to help you determine the status of the device Overview The SRX210 Services Gateway is a security device that requires the following basic configuration settings to function Interfaces must be assigned IP addresses Interfaces must be bound to zones Policies must be configured between zones to permit or deny traffic Source NAT rules must be set The device has the following...

Страница 2: ...the supplied DB 9 adapter which then connects to the serial port on the management device serial port settings 9600 8 N 1 If you are using this method to connect proceed with the CLI configuration instructions in the Branch SRX Series Services Gateways Golden Configurations at http www juniper net us en local pdf app notes 3500153 en pdf An illustration to connect a management interface Task 3 Ens...

Страница 3: ...s settings are optional If you have followed method 1 of Task 4 Obtaining a Dynamic IP Address on Your Services Gateway you can skip all the other steps and go directly to Task 7 If you have followed method 2 of Task 4 Obtaining a Static IP Address on Your Services Gateway ensure that you make the following J Web modifications 1 On the Configure System Network Settings page of the wizard enter the...

Страница 4: ...y shuts down Press the Power button again to power on the device You can reboot or halt the system in the J Web interface by selecting Maintain Reboot NOTE Use the graceful shutdown method to halt power off or reboot the services gateway Use the forced shutdown method as a last resort to recover the services gateway if the services gateway operating system is not responding to the graceful shutdow...

Отзывы: