Chapter 2 Installing the Device
18
User’s Guide
I
NSTALLING
AND
C
ONNECTING
THE
AC P
OWER
S
UPPLY
To install and connect the AC power supply to the NetScreen-ISG 2000:
1.
Slide the power supply into one of the power compartments in the back of the
system.
2.
Fasten the power supply to the system by tightening the corner screws into the
eyelets on the sides of the power supply. (If you want to install two power
supplies, repeat steps 1 and 2 for the other power supply.)
3.
Connect the female end of a standard power cord to the male connector on the
back of each power supply.
4.
Connect each power cord to a standard 100-240-volt power outlet.
5.
Turn on the power switch.
I
NSTALLING
AND
W
IRING
A
DC P
OWER
S
UPPLY
To install and connect the DC power supply to the NetScreen-ISG 2000:
1.
Slide the power supply into one of the power compartments in the back of the
system.
2.
Fasten the power supply to the system by tightening the corner screws into the
eyelets on the sides of the power supply.
3.
If you want to install two power supplies, repeat steps 1 and 2 for the remaining
power supply.
4.
Turn on the power switch.
The DC power supply, ON/OFF switch, grounding screw, and terminal blocks are located
on the faceplate of the power supply unit.
To connect the DC power supply to a grounding point at your site:
1.
Remove the hex nut on the grounding screw.
2.
Place the ground lug on the screw and tighten the hex nut securely.
Note:
Whenever you deploy two power supplies to a NetScreen-ISG 2000, connect
each to a different power source. Each power supply is intended to receive power
from separate feeds.
Note:
If there are multiple power supplies in the NetScreen-ISG 2000 and any of
them are off, the Alarm LED on the management module glows red. This
warning indicates that maximum system reliability requires all installed power
supplies to be operational.
Warning:
You must shut off current to the DC feed wires before connecting the wires to the
power supplies. Also, make sure that the ON/OFF switch is in the off position.
Содержание NETSCREEN-ISG 2000
Страница 1: ...NETSCREEN ISG 2000 User s Guide Version 5 0 P N 093 1488 000 Rev A ...
Страница 3: ...NetScreen ISG 2000 iii Language Contents English 1 French 53 ...
Страница 4: ...Language Contents iv User s Guide ...
Страница 18: ...Chapter 1 Overview 12 User s Guide ...
Страница 26: ...Chapter 2 Installing the Device 20 User s Guide ...
Страница 52: ...Chapter 4 Servicing the Device 46 User s Guide ...
Страница 56: ...Appendix A Specifications 50 User s Guide ...
Страница 58: ...Index 52 User s Guide S Status LEDs 7 T transparent mode 22 V ventilation 14 viewing port settings 31 ...
Страница 80: ...Chapitre 2 Installation de l unité 72 Manuel de l utilisateur ...
Страница 98: ...Chapitre 3 Configuration de l unité 90 Manuel de l utilisateur ...
Страница 112: ...Annexe A Spécifications 104 Manuel de l utilisateur ...
Страница 114: ...Index 106 NetScreen ISG 2000 ...