Figure 137: Installing an AC Power Supply in an MX480 Router
Replacing an MX480 AC Power Supply Cord
1.
Disconnecting an MX480 AC Power Supply Cord on page 321
2.
Connecting an MX480 AC Power Supply Cord on page 322
Disconnecting an MX480 AC Power Supply Cord
To disconnect the AC power cord:
1.
Switch off the dedicated customer site circuit breaker for the power supply, and
remove the power cord from the AC power source. Follow the instructions for your
site.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Move the AC input switch next to the appliance inlet on the power supply to the off (
O
)
position.
4.
Remove the power cord from the power supply.