WARNING:
Power connections must be performed by a licensed electrician
only.
12.
Verify that the power cable connections are correct.
13.
Screw the retaining nut onto the AC power cord to secure it to the metal wiring
compartment.
14.
Using a number 2 Phillips (+) screwdriver, tighten the two captive screws on the metal
AC wiring compartment.
15.
Use the provided plastic cable tie to fasten the AC power cord to the PDM.
16.
Verify that the AC power cord does not touch or block access to router components,
and that it does not drape where people could trip on it.
17.
Repeat the procedure for the other three-phase delta AC PDMs.
18.
Connect the three-phase delta AC power cord mating connector to the AC power
cord connector (see
).
shows the approved
three-phase delta AC power cord mating connector specifications.
Figure 35: Three-Phase Delta AC Power Cord Mating Connector
g000037
NOTE:
The three-phase delta AC power cord mating connector is not
supplied by Juniper Networks.
Table 5: Three-Phase Delta AC Power Cord Mating Cable Connector
Specifications
Description
Manufacturer Part Number
Cable
60-amp, 250 volt 3-phase,
3-pole, 4-wire, North
American pin and sleeve
connector, industrial grade,
IP67, watertight (blue)
460C9W
Three-phase delta