Table 8: JSA3800 Appliance Physical Specifications (continued)
JSA3800
Specification
10,000 ft max.
Altitude operating
35,000 ft max.
Altitude storage
781 BTU/hour
Maximum thermal output
See Also
JSA3800 Appliance Description on page 17
•
•
Additional Hardware Requirements for JSA3800 Appliance on page 28
JSA3800 Appliance Rack Requirements
The JSA3800 appliance can be installed in a four-post or two-post rack.
provides the details of requirements for rack size, clearance, airflow,
spacing of mounting brackets and flange holes, and connecting to the building structure.
Table 9: Rack Requirements for JSA3800
Specifications
Rack Requirement
A 19 in. (48.3 cm) rack as defined in Cabinets, Racks, Panels, and Associated
Equipment (document number EIA-310-D) published by the Electronics
Industry Association (http://www.eia.org).
Size
•
The outer edges of the mounting brackets extend the width of either
chassis to 19 in. (48.3 cm).
•
The front of the chassis extends approximately 1.5 in. (3.81 cm) beyond
the mounting ears.
Clearance
•
The holes within each rack set are spaced at 1-U [1.75 in. (4.5 cm)]. The
device can be mounted in any rack that provides holes or hole patterns
spaced at 1-U [1.75 in. (4.5 cm)] increments. The holes within each rack
set are spaced at 1-U [1.75 in. (4.5 cm)].
•
The device can be mounted in any rack that provides holes or hole
patterns spaced at 1-U [1.75 in. (4.5 cm)] increments.
•
The mounting brackets and front-mount flanges used to attach the
chassis to a rack are designed to fasten to holes spaced at rack distances
of 1-U (3.5 in.).
•
The mounting holes in the mounting brackets provided with the device
are spaced 1.25 in. (3.2 cm) apart (top and bottom mounting hole).
Spacing of
mounting bracket
and flange holes
Always secure the rack in which you are installing the JSA3800 appliance
to the structure of the building. If your geographical area is subject to
earthquakes, bolt the rack to the floor. For maximum stability, also secure
the rack to ceiling brackets.
Connecting to the
building structure
See Also
Additional Hardware Requirements for JSA3800 Appliance on page 28
•
27
Copyright © 2019, Juniper Networks, Inc.
Chapter 2: Site Planning, Preparation, and Specifications
Содержание JSA3800
Страница 1: ...Juniper Secure Analytics 3800 Hardware Guide Modified 2019 01 21 Copyright 2019 Juniper Networks Inc...
Страница 6: ...Copyright 2019 Juniper Networks Inc vi Juniper Secure Analytics 3800 Hardware Guide...
Страница 8: ...Copyright 2019 Juniper Networks Inc viii Juniper Secure Analytics 3800 Hardware Guide...
Страница 10: ...Copyright 2019 Juniper Networks Inc x Juniper Secure Analytics 3800 Hardware Guide...
Страница 16: ...Copyright 2019 Juniper Networks Inc xvi Juniper Secure Analytics 3800 Hardware Guide...
Страница 24: ...Copyright 2019 Juniper Networks Inc 24 Juniper Secure Analytics 3800 Hardware Guide...
Страница 30: ...Copyright 2019 Juniper Networks Inc 30 Juniper Secure Analytics 3800 Hardware Guide...
Страница 48: ...Copyright 2019 Juniper Networks Inc 48 Juniper Secure Analytics 3800 Hardware Guide...
Страница 56: ...Copyright 2019 Juniper Networks Inc 56 Juniper Secure Analytics 3800 Hardware Guide...