Juniper JSA3800 Скачать руководство пользователя страница 26

JSA3800 Appliance Physical Specifications

Table 8 on page 26

lists the specifications for the JSA3800 appliance.

Table 8: JSA3800 Appliance Physical Specifications

JSA3800

Specification

437 mm x 43 mm x 597 mm (17.2 in. x 1.7 in. x 23.5 in.)

Dimensions (D x W x H)

27.9 lb

Weight

1 year HW, 90 days SW

Warranty

5 x 5.6cm counter-rotating PWM fans

Fans

LEDs: Power, Hard Drive Activity, Network Activity, and
Universal Information

Panel Display

Front-and-rear or mid-mount

Rack mountable

2 SFP+ 10GbE LAN ports

4 RJ-45 Gigabit Ethernet LAN ports

1 RJ-45 Dedicated IPMI LAN port

6 USB 2.0 ports total (4 rear, 2 front)

1 VGA port

NOTE:

This port is not supported.

1 DB-9 COM port

Ports

650 W redundant AC-DC Power supply

AC Input: 85 - 264 V, 47 - 63 Hz

DC Output: 3 A @ +5 V standby; 54 A @ 12 V

650 W DC-DC power supply (optional)

DC Input: -40 VDC to -72 VDC, 40 A (Max)

DC Output: 3 A @ +5 V standby; 53 A @ 12 V

Power

Environmental specifications

RoHS Compliant

RoHS

32° F (0° C) to 104° F (40° C)

Temperature operating

-40° F (-40° C) to 158° F (70° C)

Temperature storage

5% - 90% noncondensing

Humidity operating

5% - 95% noncondensing

Humidity storage

Copyright © 2019, Juniper Networks, Inc.

26

Juniper Secure Analytics 3800 Hardware Guide

Содержание JSA3800

Страница 1: ...Juniper Secure Analytics 3800 Hardware Guide Modified 2019 01 21 Copyright 2019 Juniper Networks Inc...

Страница 2: ...ght 2019 Juniper Networks Inc All rights reserved The information in this document is current as of the date on the title page YEAR 2000 NOTICE Juniper Networks hardware and software products are Year...

Страница 3: ...pliance Physical Specifications 26 JSA3800 Appliance Rack Requirements 27 Additional Hardware Requirements for JSA3800 Appliance 28 Chapter 3 Initial Installation and Configuration 31 JSA3800 Installa...

Страница 4: ...Chassis Lifting Guidelines for the JSA3800 Appliance 65 Ramp Warning 66 Rack Mounting and Cabinet Mounting Warnings 66 Grounded Equipment Warning 70 Laser and LED Safety Guidelines and Warnings 71 Gen...

Страница 5: ...tatements for EMC Requirements for the JSA3800 Appliance 90 Canada 90 European Community 90 Japan 91 Korea 91 United States 91 FCC Part 15 Statement 91 Compliance Statements for Acoustic Noise for the...

Страница 6: ...Copyright 2019 Juniper Networks Inc vi Juniper Secure Analytics 3800 Hardware Guide...

Страница 7: ...Rack 36 Figure 9 Aligning the Chassis in a Rack 36 Figure 10 Installing the JSA3800 Appliance Front Rear Mounting Flush in a Four Post Rack 37 Figure 11 Securing the Brackets to the Rack 38 Figure 12...

Страница 8: ...Copyright 2019 Juniper Networks Inc viii Juniper Secure Analytics 3800 Hardware Guide...

Страница 9: ...Back Panel Components 22 Table 7 JSA3800 Ethernet Port LEDs 22 Chapter 2 Site Planning Preparation and Specifications 25 Table 8 JSA3800 Appliance Physical Specifications 26 Table 9 Rack Requirements...

Страница 10: ...Copyright 2019 Juniper Networks Inc x Juniper Secure Analytics 3800 Hardware Guide...

Страница 11: ...www juniper net documentation If the information in the latest release notes differs from the information in the documentation follow the product Release Notes Juniper Networks Books publishes books...

Страница 12: ...type the configure command user host configure Represents text that you type Bold text like this user host show chassis alarms No alarms currently active Represents output that appears on the termina...

Страница 13: ...sign community name members community ids Encloses a variable for which you can substitute one or more values square brackets edit routing options static route default nexthop address retain Identifi...

Страница 14: ...at https www juniper net us en local pdf resource guides 7100059 en pdf Product warranties For product warranty information visit https www juniper net support warranty JTAC hours of operation The JTA...

Страница 15: ...ps entitlementsearch juniper net entitlementsearch Creating a Service Request with JTAC You can create a service request with JTAC on the Web or by telephone Visit https myjuniper juniper net Call 1 8...

Страница 16: ...Copyright 2019 Juniper Networks Inc xvi Juniper Secure Analytics 3800 Hardware Guide...

Страница 17: ...mountable chassis with AC power supplies or optional DC power supplies six hot swappable hard drives 64 GB memory and two 10 Gigabit and four Gigabit Ethernet interfaces The JSA3800 appliance Respond...

Страница 18: ...ransceiver Interface Table 3 on page 18 lists the transceivers supported on the JSA3800 appliance Table 3 JSA3800 Appliance Transceiver Interface Types Description Card Model Transceiver Type Dual Rat...

Страница 19: ...escription Figure 1 on page 19 shows the front panel components of the JSA3800 appliance Figure 1 JSA3800 Front Panel Table 4 on page 19 provides information about the front panel components of the JS...

Страница 20: ...7 Turns on or off the blue light function of the U LED when used with a UID compatible motherboard Once the blue light is activated you can easily locate the appliance in very large racks and server b...

Страница 21: ...1 When blinking it indicates DataShare interface activity LAN2 2 When blinking it indicates Management interface activity LAN1 3 Unused Hard drive 4 Solidgreen Indicatesthattheappliance is receiving p...

Страница 22: ...TE You can choose any GB ports as the management port GB ports 6 4 USB ports USB ports 7 1 DB 9 COM port COM port 8 Figure 4 on page 22 shows the back panel Ethernet port LEDs of the JSA3800 appliance...

Страница 23: ...tion on page 17 JSA3800 Appliance Front Panel Description on page 19 Related Documentation JSA3800 Appliance Transceiver Interface on page 18 JSA3800 System Overview on page 17 23 Copyright 2019 Junip...

Страница 24: ...Copyright 2019 Juniper Networks Inc 24 Juniper Secure Analytics 3800 Hardware Guide...

Страница 25: ...m to function properly the airflow around the chassis must be unrestricted Allow sufficient clearance between the front and back of the chassis and adjacent equipment Ensure that there is adequate cir...

Страница 26: ...LAN ports 4 RJ 45 Gigabit Ethernet LAN ports 1 RJ 45 Dedicated IPMI LAN port 6 USB 2 0 ports total 4 rear 2 front 1 VGA port NOTE This port is not supported 1 DB 9 COM port Ports 650 W redundant AC D...

Страница 27: ...cm beyond the mounting ears Clearance The holes within each rack set are spaced at 1 U 1 75 in 4 5 cm The device can be mounted in any rack that provides holes or hole patterns spaced at 1 U 1 75 in...

Страница 28: ...such as authentication servers DNS servers internal webservers through HTTP HTTPS external websites through HTTP HTTPS optional the Juniper Networks update server through HTTP network file system NFS...

Страница 29: ...ocumentation JSA3800 System Overview on page 17 JSA3800 Chassis on page 19 JSA3800 Installation Overview on page 31 29 Copyright 2019 Juniper Networks Inc Chapter 2 Site Planning Preparation and Speci...

Страница 30: ...Copyright 2019 Juniper Networks Inc 30 Juniper Secure Analytics 3800 Hardware Guide...

Страница 31: ...is flexible and offers several options for rack mounting the hardware The different options include Installing the JSA3800 Appliance Using Front and Rear Mounting Flush in a Four Post Rack on page 34...

Страница 32: ...on page 25 Installing the JSA3800 in a Rack on page 32 Configuring the JSA3800 on page 44 Installing the JSA3800 in a Rack Installing the JSA3800 Appliance on page 32 Installing the JSA3800 Appliance...

Страница 33: ...AN connection status as shown in Figure 6 on page 33 Figure 6 JSA3800 Front Panel LEDs 4 1 Hard drive LED Information LED 5 2 Power LED LAN2 LED 3 LAN1 LED 5 Plug an RS 232 DB 9 F F cable into the con...

Страница 34: ...00 Appliance to a Management Device on page 43 Connecting the JSA3800 Appliance to Ground on page 41 Connecting the JSA3800 Appliance to a DC Power Source on page 41 Installing the JSA3800 Appliance U...

Страница 35: ...ssis clip securely into the rail extension holes b Slide the extensions toward the front of the chassis c Secure the rails with screws as shown in Figure 7 on page 35 Figure 7 Attaching the Inner Rail...

Страница 36: ...n page 36 Figure 9 Aligning the Chassis in a Rack 4 Keeping the pressure even on both sides slide the chassis rails into the rack rails until the locking tabs click into position you might have to dep...

Страница 37: ...t Rack This option is suitable for a two post equipment rack It allows the appliance to be mid mounted so that there is even clearance at the front and rear of the rack To mount the appliance using th...

Страница 38: ...ackets to the Rack 3 Mount the outer rails on the rack by securing the racks to the brackets using M5 screws as shown in Figure 12 on page 39 Copyright 2019 Juniper Networks Inc 38 Juniper Secure Anal...

Страница 39: ...Secure an additional bracket to the front of each outer rail using two M5 screws as shown in Figure 13 on page 39 Figure 13 Securing Brackets to the Outer Rail 39 Copyright 2019 Juniper Networks Inc...

Страница 40: ...ont of the outer rails as shown in Figure 15 on page 40 7 Keeping the pressure even on both sides slide the chassis rails into the rack rails 8 Insert and tighten the thumbscrews See Figure 15 on page...

Страница 41: ...ur geographical location NOTE A ground connection to the protective earthing terminal is not required foranAC poweredJSA3800 TheACpowercordsprovideadequategrounding when you plug the power supply in t...

Страница 42: ...switch the circuit breaker to the OFF position and tape the switch handle of the circuit breaker in the OFF position To connect the DC source power to the JSA3800 appliance 1 Ensure that the input cir...

Страница 43: ...ance Back Panel Description on page 21 NOTE You can choose any GB ports as the management port To connect a management device with the JSA3800 appliance 1 Connect external devices using the ports on t...

Страница 44: ...ptop to connect to the appliance you must use a terminal program such as HyperTerminal to connect to the appliance 1 At the console prompt log in as root default username No password is required when...

Страница 45: ...ement interface and select Next 15 To configure the JSA network settings enter the values for the following parameters Use the up or down arrow keys to navigate the fields Hostname Type a fully qualif...

Страница 46: ...JSA Interface on page 46 JSA3800 Appliance Physical Specifications on page 26 Connecting the JSA3800 Appliance to a Management Device on page 43 Accessing the JSA Interface Purpose To access a Junipe...

Страница 47: ...for the JSA appliance to upgrade to a higher version If you have a temporary license the upgrade will fail run the installer again to upgrade to a higher version See Also Configuring the Basic Settin...

Страница 48: ...Copyright 2019 Juniper Networks Inc 48 Juniper Secure Analytics 3800 Hardware Guide...

Страница 49: ...Mirroring Copy data to more than one disk Striping Split data across more than one disk Error correction Redundant data storage to detect and resolve problems The JSA3800 appliance ships with hot swap...

Страница 50: ...ly fails the second power supply takes over the entire power load NOTE The JSA3800 appliance also supports DC power supply modules To maintain the power supplies follow these guidelines Ensure that th...

Страница 51: ...ement power supply 6 Using both hands slide the replacement power supply straight into the chassis until the power supply is fully seated in the chassis slot Make sure the tab on the power supply clic...

Страница 52: ...ance on page 52 Replacing a DC Power Supply on the JSA3800 Appliance To replace a DC power supply 1 Switch off the dedicated facility circuit breaker for the power supply being removed 2 Make sure tha...

Страница 53: ...ircuit breakers for all the cables attached to the power supply Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active du...

Страница 54: ...e to a DC Power Source on page 41 Related Documentation Connecting the JSA3800 Appliance to a DC Power Source on page 41 JSA3800 Chassis on page 19 Copyright 2019 Juniper Networks Inc 54 Juniper Secur...

Страница 55: ...your 12 digit case number followed by the key if this is an existing case or press the key to be routed to the next available support engineer When requesting support from JTAC by telephone be prepar...

Страница 56: ...Copyright 2019 Juniper Networks Inc 56 Juniper Secure Analytics 3800 Hardware Guide...

Страница 57: ...d LED Safety Guidelines and Warnings on page 71 Radiation from Open Port Apertures Warning on page 73 Maintenance and Operational Safety Guidelines and Warnings on page 74 Action to Take After an Elec...

Страница 58: ...k letsel kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico s en dient u op de hoogte te zijn van standaard maa...

Страница 59: ...e accidentes Varning Denna varningssymbol signalerar fara Du befinner dig i en situation som kan leda till personskada Innan du utf r arbete p n gon utrustning m ste du vara medveten om farorna med el...

Страница 60: ...liquid onto the chassis or onto any device component Such an action could cause electrical shock or damage the device Avoid touching uninsulated electrical wires or terminals that have not been discon...

Страница 61: ...in un area ad accesso limitato Un area ad accesso limitato un area accessibile solo a personale di assistenza tramite un attrezzo speciale lucchetto o altri dispositivi di sicurezza ed controllata dal...

Страница 62: ...ut dette utstyret Aviso Este equipamento dever ser instalado ou substitu do apenas por pessoal devidamente treinado e qualificado Atenci n Estos equipos deben ser instalados y reemplazados exclusivame...

Страница 63: ...bare metal of the device to ground yourself before handling the component Avoid contact between the component that is subject to ESD damage and your clothing ESD voltages emitted from clothing can dam...

Страница 64: ...f to the equipment at the source Then use a Type C fire extinguisher which uses noncorrosive fire retardants to extinguish the fire Fire Suppression Equipment Type C fire extinguishers which use nonco...

Страница 65: ...Sie das System an die Stromquelle anschlie en AvvertenzaConsultareleistruzionidiinstallazioneprimadicollegareilsistema all alimentatore Advarsel Les installasjonsinstruksjonene f r systemet kobles til...

Страница 66: ...t use a ramp inclined at more than 10 degrees Waarschuwing Gebruik een oprijplaat niet onder een hoek van meer dan 10 graden Varoitus l k yt sellaista kaltevaa pintaa jonka kaltevuus ylitt 10 astetta...

Страница 67: ...onderaan in het rek gemonteerd te worden als het toestel het enige in het rek is Wanneer u dit toestel in een gedeeltelijk gevuld rek monteert dient u het rek van onderen naar boven te laden met het z...

Страница 68: ...cht werden Bei Anbringung dieser Einheit in einem zum Teil gef llten Gestell ist das Gestell von unten nach oben zu laden wobei das schwerste Bauteil unten im Gestell anzubringen ist Wird das Gestell...

Страница 69: ...fixa estrutura do edificio Esta unidade dever ser montada na parte inferior da estante caso seja esta a nica unidade a ser montada Ao montar esta unidade numa estante parcialmente ocupada coloque os...

Страница 70: ...computer tijdens normaal gebruik met aarde is verbonden Varoitus T m laitteisto on tarkoitettu maadoitettavaksi Varmista ett is nt laite on yhdistetty maahan normaalik yt n aikana Attention Cet quipe...

Страница 71: ...into unterminated ports or at fibers that connect to unknown sources Do not examine unterminated optical ports with optical instruments Avoid direct exposure to the beam WARNING Unterminated optical c...

Страница 72: ...ruments Waarschuwing Niet in de straal staren of hem rechtstreeks bekijken met optische instrumenten Varoitus l katso s teeseen l k tarkastele sit suoraan optisen laitteen avulla Attention Ne pas fixe...

Страница 73: ...ittieren wenn kein Glasfaserkabel angeschlossen ist Vermeiden Sie es sich den Strahlungen auszusetzen und starren Sie nicht in die ffnungen Avvertenza Quando i cavi in fibra non sono inseriti radiazio...

Страница 74: ...tajan suosittelema H vit k ytetyt akut valmistajan ohjeiden mukaan Attention Danger d explosion si la pile n est pas remplac e correctement Ne la remplacer que par une pile de type semblable ou quival...

Страница 75: ...n lassen Varoitus Ennen kuin ty skentelet voimavirtajohtoihin kytkettyjen laitteiden parissa ota pois kaikki korut sormukset kaulakorut ja kellot mukaan lukien Metalliesineet kuumenevat kun ne ovat yh...

Страница 76: ...arbetar p utrustning som r kopplad till kraftledningar Metallobjekt hettas upp n r de kopplas ihop med str m och jord och kan f rorsaka allvarliga br nnskador metallobjekt kan ocks sammansvetsas med k...

Страница 77: ...teurs de la gamme Juniper Networks switch ne l utilisez pas dans une zone o la temp rature ambiante est sup rieure 40 C Pour permettre un flot d air constant d gagez un espace d au moins 15 2 cm autou...

Страница 78: ...lations Waarschuwing Dit produkt dient volgens alle landelijke wetten en voorschriften te worden afgedankt Varoitus T m n tuotteen lopullisesta h vitt misest tulee huolehtia kaikkia valtakunnallisia l...

Страница 79: ...device are suitable for connection to intrabuilding or unexposed wiring or cabling only The addition of primary protectors is not sufficient protection for connecting these interfaces metallically to...

Страница 80: ...be used at the AC power source The following electrical safety guidelines apply to AC powered devices Note the following warnings printed on the device CAUTION THIS UNIT HAS MORE THAN ONE POWER SUPPLY...

Страница 81: ...the ground stud Run two wires from the circuit breaker box to a source of 38 VDC A DC powered device that is equipped with a DC terminal block is intended only for installation in a restricted access...

Страница 82: ...it het stopcontact te halen Varoitus Kytke irti vaihtovirtalaitteiden virtajohto ennen kuin teet mit n asennuspohjalle tai ty skentelet virtal hteiden l heisyydess Attention Avant de travailler sur un...

Страница 83: ...quer l une quelconque des proc dures ci dessous v rifier que le circuit en courant continu n est plus sous tension Pour en tre s r localiser le disjoncteur situ sur le panneau de service du circuit en...

Страница 84: ...pplare i FR N l get DC Power Grounding Requirements and Warning An insulated grounding conductor that is identical in size to the grounded and ungrounded branch circuit supply conductors but is identi...

Страница 85: ...tilisant les crochets appropri s l extr mit de c blage En reliant la puissance l ordre appropri de c blage est rectifi pour rectifier RTN RTN puis 48 V 48 V En d branchant la puissance l ordre appropr...

Страница 86: ...ngssekvens ar jord till jord RTN till RTN 48 V till 48 V Korrekt kopplas kopplingssekvens ar 48 V till 48 V RTN till RTN jord till jord DC Power Wiring Terminations Warning WARNING When stranded wirin...

Страница 87: ...ina es de cabo em circuito fechado e planas com terminais de orelha voltados para cima Estas termina es de cabo dever o ser do tamanho apropriado para os respectivos cabos e dever o prender simultanea...

Страница 88: ...remover a fonte de alimenta o de energia dever o ser desconectadas todas as conex es existentes Atenci n Esta unidad tiene m s de una conexi n de suministros de alimentaci n para eliminar la alimentac...

Страница 89: ...n and requirements EMC FCC 47CFR Part 15 Class A 2009 USA Radiated Emissions EN 55022 2006 A1 2007 European Radiated Emissions ICES 003 Issue 4 Feb 2004 Canada Radiated Emissions VCCI V 3 2013 04 and...

Страница 90: ...e individual service can be extended by means of a certified connector assembly The customer should be aware that compliance with the above conditions might not prevent degradation of service in some...

Страница 91: ...es and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual might cause harmful interference to radio communications Operation of this equipment i...

Страница 92: ...umentation Compliance Statements for Acoustic Noise for the JSA3800 Appliance on page 92 Agency Approvals for the JSA3800 Appliance on page 89 Installation Instructions Warning on page 65 Compliance S...

Отзывы: