CHAPTER 21
Monitoring Hardware Components
•
•
•
•
Maintaining the JSA7500 Air Filter on page 136
RAID Array
The JSA appliance ships with hot-swappable hard disks to offer component redundancy.
The JSA1500 appliance has a RAID1 configuration. The second (redundant) disk maintains
a copy of the software image and configuration information on the working hard disk. If
the working hard disk fails, the redundant hard disk immediately assumes responsibility
for JSA operations. JSA3500, JSA5500, and JSA7500 have RAID10 configuration. You
can hot-swap the disk if any one of the disks fails.
Redundant array of independent disk (RAID) is an organization of multiple disks of fault
tolerance and performance. A RAID array is used in the servers for data storage and to
replicate data among multiple hark disk drives. There are different RAID levels designed
to increase data reliability and I/O performance.
The key concepts in RAID are:
•
Mirroring—copy data to more than one disk
•
Striping—split data across more than one disk
•
Error correction—redundant data storage to detect and resolve problems
JSA1500 uses RAID1, and JSA3500, JSA5500, and JSA7500 use RAID10. RAID1 uses
mirroring and duplex techniques to copy data to the redundant disk. In RAID10, drives
are duplicated for fault tolerance.
To monitor the RAID array, use the following commands:
•
For JSA1500, JSA3500, and JSA5500 volume status:
sas2ircu Ø status
For example,
[root@localhost ~]# sas2ircu Ø status
•
For JSA1500, JSA3500, and JSA5500 device status:
133
Copyright © 2018, Juniper Networks, Inc.
Содержание JSA3500
Страница 1: ...Juniper Secure Analytics Hardware Guide Modified 2018 09 05 Copyright 2018 Juniper Networks Inc...
Страница 16: ...Copyright 2018 Juniper Networks Inc xvi Juniper Secure Analytics Hardware Guide...
Страница 17: ...PART 1 Overview Introduction on page 3 1 Copyright 2018 Juniper Networks Inc...
Страница 18: ...Copyright 2018 Juniper Networks Inc 2 Juniper Secure Analytics Hardware Guide...
Страница 22: ...Copyright 2018 Juniper Networks Inc 6 Juniper Secure Analytics Hardware Guide...
Страница 30: ...Copyright 2018 Juniper Networks Inc 14 Juniper Secure Analytics Hardware Guide...
Страница 36: ...Copyright 2018 Juniper Networks Inc 20 Juniper Secure Analytics Hardware Guide...
Страница 40: ...Copyright 2018 Juniper Networks Inc 24 Juniper Secure Analytics Hardware Guide...
Страница 46: ...Copyright 2018 Juniper Networks Inc 30 Juniper Secure Analytics Hardware Guide...
Страница 50: ...Copyright 2018 Juniper Networks Inc 34 Juniper Secure Analytics Hardware Guide...
Страница 51: ...PART 3 Planning Site Preparation on page 37 35 Copyright 2018 Juniper Networks Inc...
Страница 52: ...Copyright 2018 Juniper Networks Inc 36 Juniper Secure Analytics Hardware Guide...
Страница 56: ...Copyright 2018 Juniper Networks Inc 40 Juniper Secure Analytics Hardware Guide...
Страница 58: ...Copyright 2018 Juniper Networks Inc 42 Juniper Secure Analytics Hardware Guide...
Страница 66: ...Copyright 2018 Juniper Networks Inc 50 Juniper Secure Analytics Hardware Guide...
Страница 84: ...Copyright 2018 Juniper Networks Inc 68 Juniper Secure Analytics Hardware Guide...
Страница 104: ...Copyright 2018 Juniper Networks Inc 88 Juniper Secure Analytics Hardware Guide...
Страница 112: ...Copyright 2018 Juniper Networks Inc 96 Juniper Secure Analytics Hardware Guide...
Страница 118: ...Copyright 2018 Juniper Networks Inc 102 Juniper Secure Analytics Hardware Guide...
Страница 128: ...Copyright 2018 Juniper Networks Inc 112 Juniper Secure Analytics Hardware Guide...
Страница 132: ...Copyright 2018 Juniper Networks Inc 116 Juniper Secure Analytics Hardware Guide...
Страница 137: ...PART 6 Maintenance Maintaining the Hardware on page 123 121 Copyright 2018 Juniper Networks Inc...
Страница 138: ...Copyright 2018 Juniper Networks Inc 122 Juniper Secure Analytics Hardware Guide...
Страница 148: ...Copyright 2018 Juniper Networks Inc 132 Juniper Secure Analytics Hardware Guide...
Страница 154: ...Copyright 2018 Juniper Networks Inc 138 Juniper Secure Analytics Hardware Guide...