AC Power Cord Specifications for an EX9253 Switch
A detachable AC power cord is supplied with the AC power supplies. The coupler is type C13 as
described by International Electrotechnical Commission (IEC) standard 60320. The plug end of the
power cord fits into the power source outlet that is standard for your geographical location.
CAUTION: The AC power cord provided with each power supply is intended for use
with that power supply only and not for any other use.
NOTE: In North America, AC power cords must not exceed 4.5 meters in length, to comply with
National Electrical Code (NEC) Sections 400-8 (NFPA 75, 5-2.2) and 210-52 and Canadian
Electrical Code (CEC) Section 4-010(3). The cords supplied with the switch are in compliance.
gives the AC power cord specifications for the countries and regions listed in the
table.
Table 8: AC Power Cord Specifications
Country/Region
Electrical Specifications
Plug Standards
Juniper Model Number
Argentina
250 VAC, 10 A, 50 Hz
IRAM 2073 Type RA/3
CBL-EX-PWR-C13-AR
Australia
250 VAC, 10 A, 50 Hz
AS/NZZS 3112 Type
SAA/3
CBL-EX-PWR-C13-AU
Brazil
250 VAC, 10 A, 50 Hz
NBR 14136 Type BR/3
CBL-EX-PWR-C13-BR
China
250 VAC, 10 A, 50 Hz
GB 1002-1996 Type
PRC/3
CBL-EX-PWR-C13-CH
Europe (except Italy,
Switzerland, and United
Kingdom)
250 VAC, 10 A, 50 Hz
CEE (7) VII Type VIIG
CBL-EX-PWR-C13-EU
India
250 VAC, 10 A, 50 Hz
IS 1293 Type IND/3
CBL-EX-PWR-C13-IN