• Issue the
show chassis fpc
command to check the status of installed line cards. As shown in the sample
output, the value
Online
in the column labeled
Slot State
indicates that the line card is functioning
normally:
user@switch> show chassis fpc
Temp CPU Utilization (%) CPU Utilization (%) Memory Utilization
(%)
Slot State (C) Total Interrupt 1min 5min 15min DRAM (MB)
Heap Buffer
0 Online 52 17 0 20 22 23 3136 12 11
1 Empty
NOTE: The
show chassis fpc
command displays the status of the line cards.
For more detailed output, add the
detail
option. The following example does not specify a slot
number, which is optional:
user@switch> show chassis fpc detail
Slot 0 information:
State Online
Total CPU DRAM 3136 MB
Total RLDRAM 771 MB
Total DDR DRAM 18432 MB
Temperature 52 degrees C / 125 degrees F
Start time 2018-06-14 00:37:49 UTC
Uptime 30 minutes, 35 seconds
Max MPC base power consumption 910 Watts
Max MIC1 power consumption 155 Watts
Max MPC total power consumption 1065 Watts