EX4100 and EX4100-F Power System
IN THIS SECTION
AC Power Supply in EX4100 and EX4100-F Switches | 68
DC Power Supply in EX4100 Switches | 78
Power Supply LEDs in EX4100 Switches | 81
AC Power Supply in EX4100 and EX4100-F Switches
IN THIS SECTION
Characteristics of an AC Power Supply | 69
Specifications of the AC Power Supplies Used in EX4100 and EX4100-F Switches | 71
Specifications of the Power Cord for AC Power Supplies for EX4100 and EX4100-F Switches | 75
Juniper Networks ships EX4100 switches with one power supply installed in the rear panel. You can
install up to two power supplies in an EX4100 switch. The power supply slots are numbered 0 and 1,
and each slot has a power icon next to it. The power supplies support front-to-back airflow or back-to-
front airflow. They are fully redundant, load-sharing, hot-removable and hot-insertable field-replaceable
units (FRUs).
Hot-removable and hot-insertable mean that when the second power supply is installed
and running, you can remove and replace the power supplies without powering off the switch or
disrupting switch functions. This topic describes the AC power supplies that EX4100 switches support.
68
Содержание EX4100
Страница 1: ...EX4100 and EX4100 F Switch Hardware Guide Published 2022 11 08 ...
Страница 68: ...Figure 45 Front to Back Airflow Through the EX4100 48P or EX4100 48T Switch Chassis 59 ...
Страница 69: ...Figure 46 Front to Back Airflow Through the EX4100 24MP or EX4100 48MP Switch Chassis 60 ...
Страница 70: ...Figure 47 Front to Back Airflow Through the EX4100 F 24P Switch Chassis 61 ...
Страница 71: ...Figure 48 Front to Back Airflow Through the EX4100 F 24T Switch Chassis 62 ...
Страница 72: ...Figure 49 Front to Back Airflow Through the EX4100 F 48P Switch Chassis 63 ...
Страница 105: ...Figure 62 Clearance Requirements for Airflow and Hardware Maintenance for the EX4100 24MP and EX4100 48MP Switch 96 ...
Страница 106: ...Figure 63 Clearance Requirements for Airflow and Hardware Maintenance for the EX4100 F 24T Switch 97 ...
Страница 107: ...Figure 64 Clearance Requirements for Airflow and Hardware Maintenance for the EX4100 F 24P Switch 98 ...
Страница 108: ...Figure 65 Clearance Requirements for Airflow and Hardware Maintenance for the EX4100 F 48P Switch 99 ...
Страница 209: ...5 CHAPTER Troubleshoot Hardware Troubleshoot the EX4100 and EX4100 F Components 201 ...