Table 29: Alarm Contact Connector Pinouts (continued)
Function
CLI Port Mapping
Direction
Signal Definition
Pin
Number
External alarm output 1 (this pin is
connected to Pin 13 in closed condition)
Output Alarm Port 1
Output
ALARM_OUT1_REF
14
External alarm output 2 (this pin is
connected to Pin 9 in closed condition)
Reserved for Major
alarm
Output
ALARM_OUT2_NO/NC
15
SEE ALSO
ACX2000 and ACX2100 Universal Metro Router Overview | 17
Front Panel of an ACX2000 Router | 47
LEDs on ACX2000 and ACX2100 Routers | 57
Management Port Connector Pinout Information for ACX Series Routers
The management port— labeled MGMT— on an ACX Series router uses an RJ-45 connector to connect
to a management device for out-of-band management.
The port uses an autosensing RJ-45 connector to support a 10/100BASE-T connection. Two LEDs indicate
link activity on the port and the administrative status of the port.
provides the pinout information for the RJ-45 connector for the management port.
Table 30: Management Port Connector Pinout Information
Direction
Description
Pin
In/Out
TRD[0]-
1
In/Out
TRD[0]+
2
In/Out
TRD[1]-
3
In/Out
TRD[1]+
4
In/Out
TRD[2]-
5
87
Содержание ACX2000
Страница 1: ...ACX2000 and ACX2100 Universal Metro Router Hardware Guide Published 2020 09 07 ...
Страница 91: ...Front Panel of an ACX2000 Router 47 LEDs on ACX2000 and ACX2100 Routers 57 91 ...
Страница 116: ...4 CHAPTER Maintaining Components Maintaining ACX2000 and ACX2100 Components 117 ...
Страница 125: ...5 CHAPTER Troubleshooting Hardware Troubleshooting ACX2000 and ACX2100 126 ...
Страница 139: ...139 ...
Страница 144: ...Restricted Access Warning 144 ...
Страница 148: ...148 ...
Страница 161: ...Jewelry Removal Warning 161 ...
Страница 164: ...Operating Temperature Warning 164 ...
Страница 174: ...DC Power Disconnection Warning 174 ...
Страница 178: ...DC Power Wiring Sequence Warning 178 ...
Страница 181: ...DC Power Wiring Terminations Warning 181 ...