Table 8: PoE Port Features
Description
Feature
IEEE 802.3af (PoE) and IEEE 802.3at (PoE+)
Supported standards
65 W
Per port power limit
Copper Ethernet LAN cable
Cable
RJ-45
Connector
0/1/3 POE and 0/1/7 POE
Port numbering (hardware)
ge-0/1/3 and ge-0/1/7
Port numbering (software)
Gigabit Ethernet SFP Ports
The GE ports described in
support small form-factor pluggable (SFP) transceivers.
NOTE:
On the ACX2000 router, you can use Gigabit Ethernet transceivers in the GE ports, or
you can use 10-Gigabit Ethernet transceivers in the XE ports. Use one set of ports at a time. On
the ACX2100 router, you can use both sets at the same time.
Table 9: SFP Port Features
Description
Feature
See the Hardware Compatibility Tool for the specifications of transceivers
supported on the ACX2000 or ACX2100. The list of supported transceivers
for the ACX2000 is located at
https://pathfinder.juniper.net/hct/product/#prd=ACX2000
. The list of
supported transceivers for the ACX2100 is located at
https://pathfinder.juniper.net/hct/product/#prd=ACX2100
Supported standards
Cable
Connector
•
ACX2000: 0/2/0 and 0/2/1
•
ACX2100: 1/1/0 through 1/1/3 and 1/2/0 and 1/2/1
Port numbering (hardware)
•
ACX2000: ge-0/2/0 and ge-0/2/1
•
ACX2100: ge-1/1/0 through ge-1/1/3 and ge-1/2/0 and ge-1/2/1
Port numbering (software)
53
Содержание ACX2000
Страница 1: ...ACX2000 and ACX2100 Universal Metro Router Hardware Guide Published 2020 09 07 ...
Страница 91: ...Front Panel of an ACX2000 Router 47 LEDs on ACX2000 and ACX2100 Routers 57 91 ...
Страница 116: ...4 CHAPTER Maintaining Components Maintaining ACX2000 and ACX2100 Components 117 ...
Страница 125: ...5 CHAPTER Troubleshooting Hardware Troubleshooting ACX2000 and ACX2100 126 ...
Страница 139: ...139 ...
Страница 144: ...Restricted Access Warning 144 ...
Страница 148: ...148 ...
Страница 161: ...Jewelry Removal Warning 161 ...
Страница 164: ...Operating Temperature Warning 164 ...
Страница 174: ...DC Power Disconnection Warning 174 ...
Страница 178: ...DC Power Wiring Sequence Warning 178 ...
Страница 181: ...DC Power Wiring Terminations Warning 181 ...