![Jungheinrich ERC 14 Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/jungheinrich/erc-14/erc-14_operating-instructions-manual_2032032054.webp)
E 27
0602
.GB
7.1
Discharge monitor function
With the discharge monitor function enabled, the lifting function switches of when
reaching the discharge limit (the Stop LED switches on). Travelling and lowering is
still possible. For wet batteries the residual capacity is 20%, for maintenance-free
batteries it is 40%. At 30% resp. 50% the batteries should be recharged (the yellow
LED lights up as warning indication).
7.2
Operating hours display
Display range between 0.0 and 99,999.0 hours. Travel and lifting movements are
logged. This is a backlit display.
A
For maintenance-free batteries a “T” symbol is shown in the display.
Error messages
The operating hours display is also used for indicating errors. The display shows a
“C” for a component and then a three-digit component number. When an error occurs,
an “E” is shown with a three-digit error number.
If several errors occur they are displayed one after the other. Errors are displayed as
long as they persist. The operating hours display is overwritten with an error
message. Most errors cause the emergency stop to be triggered. The error display is
maintained until the control circuit is switched off (key switch).
A
The service personnel has access to detailed component descriptions and error
codes.
Display for parameter changes (travel programmes)
The parameter numbers are shown in the display. This is done in conjunction with the
keyboard (CANCODE).
The display has the format “PPPVVV”. “P” is the parameter number, “V” is a value.
After a few seconds the display is overwritten again by the operating hours display.
7.3
Switch-on test
After switching on the display shows:
– the software version
– the operating hours
– the charging condition
E 27
0602
.GB
7.1
Discharge monitor function
With the discharge monitor function enabled, the lifting function switches of when
reaching the discharge limit (the Stop LED switches on). Travelling and lowering is
still possible. For wet batteries the residual capacity is 20%, for maintenance-free
batteries it is 40%. At 30% resp. 50% the batteries should be recharged (the yellow
LED lights up as warning indication).
7.2
Operating hours display
Display range between 0.0 and 99,999.0 hours. Travel and lifting movements are
logged. This is a backlit display.
A
For maintenance-free batteries a “T” symbol is shown in the display.
Error messages
The operating hours display is also used for indicating errors. The display shows a
“C” for a component and then a three-digit component number. When an error occurs,
an “E” is shown with a three-digit error number.
If several errors occur they are displayed one after the other. Errors are displayed as
long as they persist. The operating hours display is overwritten with an error
message. Most errors cause the emergency stop to be triggered. The error display is
maintained until the control circuit is switched off (key switch).
A
The service personnel has access to detailed component descriptions and error
codes.
Display for parameter changes (travel programmes)
The parameter numbers are shown in the display. This is done in conjunction with the
keyboard (CANCODE).
The display has the format “PPPVVV”. “P” is the parameter number, “V” is a value.
After a few seconds the display is overwritten again by the operating hours display.
7.3
Switch-on test
After switching on the display shows:
– the software version
– the operating hours
– the charging condition
Содержание ERC 14
Страница 1: ...Operating instructions 50126632 ERC ERC Z 12 14 16 G 10 01 06 02...
Страница 3: ...0108 GB...
Страница 7: ...0600 GB A 2...
Страница 27: ...1001 GB D 10...
Страница 30: ...E 3 0602 GB 11 10 8 6 7 5 5 9 1 17 4 14 13 12 15 16 2 3...
Страница 32: ...E 5 0602 GB 11 10 8 6 7 5 5 9 1 17 4 14 13 12 15 16 2 3...