D*AP4
19
Sync Source Information
You will get detailed information about the measured rates of possible sync sources
System Clock
Sample Rate
[Follow Input / 44.1 / 48 / 88.2 / 96]
Fallback Sample Rate
[44.1 / 48 / 88.2 / 96]]
Fallback Video rate
[25 / 29,97 / 30]
Sync Source Priority
Choice 1 – 4
[OFF / Internal / Sync-In WCLK / Sync-In AES /
Interface 1 [SDI I/O if fitted] / Sync-In Black Burst/Tri-Level]
Fallback on Sync Error:
[Internal]
If the selected sync source is not available the next source will be
selected. If none of the pre selected sync source is not available,
the source will fall back to the internal clock oscillator
AES Select
[Sync-In AES / Input AES 1/2 XLR / Input AES 1/2 BNC]
Select from which physical input the AES sync must be taken.
Accept SDI Generator
[ON / OFF]
For rare application you may use the SDI generator (if an SDI I/O
interface is installed) as the sync source. In this case downstream
equipment must be synchronized to the D*AP4 LM.
See INTERFACES > SDI I/O interface > Setup for details.
Important note! It is not possible to gen lock the SDI generator. The generator will run on its own
internal 27MHz crystal clock.
Setup GUI – SYSTEM – Remote Access – X*AP Remote
You can control pre-settings of the EVENTS system via remote access from the X*AP remote panel or from a
mobile UI on a tablet, a smart phone or even via a browser session from any PC in the network.
To better understand the possibilities of these settings it is recommended to study the comprehensive
EVENTS system of the D*AP4.