Tronic Transformers 

 

 
 

In TRONIC transformers without stress-relief, the cable must be 
protected against pushing and pulling with a suitable clamp at the 
TRONIC transformer.  
For TRONIC transformers with prepared connecting cable, a suitable box 
to connect the mains supply must be used. 
For TRONIC transformers equipped with a stressrelieving device, use at 
least a H 05 VV-F 2x1.5 mm² cable for the mains supply. Stripping length 
for outer cable sheath and base insulation: see fig. (8). 

 

Figure 8 

Important: When TRONIC transformers with multipoint terminals on 
the primary side for mains supply through-connection are used, the 
maximum number of interconnected TRONIC transformers is limited 
to 10. 

4. Technical 

data 

 

10-40 W  

Trafo 

20-70 W  

Trafo 

20-70 W  

Trafo 

20-105 W  

Trafo 

20-150 W  

Trafo 

50-200 W  

Trafo 

Design / 
Dimension (mm) 

 

73 x 35,5 x 

18 

 

49 x 48 x 28 

 

152 x 43,5x 

17,5 

 

175 x 42 x 18 

 

176 x 42 x 38 

 

212 x 48,5 x 46 

Nominal rating 

10-40 W T50 

20-60 W T50 
20-70 W T40 

20-70 W T50 

20-105 W T50 

20-150 W T50 

50-200 W T50 

Supply voltage 

AC 230 V ~ 

Mains frequency 

50 / 60 Hz 

50 / 60 Hz 

50 / 60 Hz 

50 / 60 Hz 

50 / 60 Hz 

50 Hz 

Output voltage 

11,7 V eff 

~ 50 kHz 

11,7 V eff 

~ 40 kHz 

11,7 V eff 

~ 40 kHz 

11,8 V eff 

~ 40 kHz 

11,7 V eff 

~ 40 kHz 

11,5 V eff 

~ 40 kHz 

Primary current 

0,18 A  

(40 W) 

0,33 A 

(60 W) 

0,33 A  

(70 W) 

0,45 A  

(105 W) 

0,71 A  

(150 W) 

0,95 A  

(200 W) 

Max. ambient 
temperature 

50 °C 

50 °C (60 W) 

50 °C 

50 °C 

50 °C 

45 °C 

Max. housing 
temperature 

85 °C 

75 °C 

90 °C 

80 °C 

75 °C 

65 °C 

Max. length of 
secondary line 

2 m 

2 m 

2 m 

2 m 

2 m 

2 m 

Figure 9 

 