Smart Visu Server

11.08.2020

2 / 4

0024074401

3  Function

System information

The Smart Visu Server is used to visualise and operate (SV-Home) a KNX system connected to the same network via 

a smartphone, tablet, laptop or PC and to control third-party IoT systems (e.g. Philips Hue).

A local network is required for it to function.

The connection to the KNX is made via the KNX IP interface.

The connection to the third-party IoT systems is made via the system devices recommended by the manufacturer 

(e.g. Philips Hue Bridge).

Start-up takes place via the web-based interface (SV-Control).

The technical documentation is also available here.

The server organises functions of the connected systems into areas, functions and actions.

Area:   

 An area indicates an assignment, e.g. to a room.

Function: 

 A function corresponds to, for example, a KNX function, thus possibly comprising multiple group 

addresses, e.g. switching channel with feedback. A function could also be the link to a Philips Hue 

lamp.

Action:   

 An action is a grouping of one or more functions. Actions can be triggered by events, by time or via 

user-defined controls.

KNX projects can be imported from the OPC export (3-level group address) of ETS3, ET4 or ETS5 or be created 

manually.

Intended use

 - Visualisation and operation of KNX systems via devices with HTML5 browser or app (iOS, Android), 

e.g. smartphone, tablet, laptop, PC, etc.

 -

Operation in local IP networks that support DHCP (Dynamic Host Configuration Protocol), or with static 

IP address (IPv4)

 - Operation indoors

 

i

Further information about this device can be found in the operation manual on our website.

Scope of delivery

 - Smart Visu Server including software

 - Retaining bracket for wall or support rail mounting

 - Operating instructions

 - Power supply unit with plug 

 - SV-SERVER: EU power supply unit (Euro plug)

 - SV-SERVER-INT:  Power supply unit, including adapter for BS (United Kingdom), EU (Euro plug) and CN (China)

4  Information for electrically skilled persons

Installation and electrical connection

DANGER 

Electrical shock on contact with live parts in the installation environment.

 

Electrical shocks can be fatal. 

Before working on the device, disconnect the power and cover live parts in the area!

Installation

Mounting takes place using the supplied retaining unit on the wall or on a support rail according to DIN EN 60715. 

The server is snapped onto the retaining unit.