background image

Emergency system set and emergency system set with UPS

01.10.2020

8 / 11

0024015123

7 Connection terminals

Emergency signal

Ref-No.: NRS .. 0834 RM ..

Visual and acoustical call identification, floating contact.

+24V

M GND

KW

KR

KA

+24VE GNDE

RT BL AT

Fig. 13:  Emergency signal (rear side)

+24VE 

+24V external

GNDE 

GND external

RT 

Call button

BL 

Status light

AT 

Reset button

KA 

Make contact

KR 

Break contact

KW 

Contact input

Service unit terminal

GND 

Power supply –

+24V 

Power

The external connections are intended for downstreamed components (pull cord push-buttons, reset buttons, ...).

Pull cord push-button

Ref-No.: NRS .. 0834 ZT..

Pull cord push-button with status light

RL

WC

R

TWC

R

TWC\

+24V

Fig. 14:  Pull cord push-button

RLWC Light

RTWC 

Pull cord push-button (IN)

RTWC\ 

Pull cord push-button (OUT)

+24V 

Power

Содержание NRS 0834 Series

Страница 1: ...uctions are an integral part of the product and must remain with the end customer 2 Battery safety instructions WARNING Improper handling of batteries can result in explosion fire or chemical burn due...

Страница 2: ...5 6 7 Fig 2 Pull cord push button 4 Insert pull cord push button 5 Cover pull cord push button 6 Pull cord 7 Status light 8 2 9 10 Fig 3 Reset button 8 Insert reset button 9 Cover reset button 10 Res...

Страница 3: ...uded in the emergency system set with UPS 14 UPS module 15 2 16 18 17 Fig 6 Service unit not included in the set 15 Insert service unit 16 Cover service unit 17 Reset visual call 18 Reset acoustical c...

Страница 4: ...ctivate call with reset button 6 Information for electrically skilled persons Installation and electrical connection Mounting height according to DIN VDE 0834 call systems in hospitals nursing homes a...

Страница 5: ...cy system Installation see fig 1 2 3 4 5 6 7 Connection see fig 9 10 Wiring see fig 11 Connecting UPS module Only connect accumulator with UPS module after connecting main power supply to avoid discha...

Страница 6: ...call button Reset button RT WC BL 24V 24VE only included in the emergency system set with UPS GNDE 24V IN 24V OUT Fig 9 Wiring plan 24V M GND 24V M GND KW KR KA 24VE GNDE RT BL AT RLWC RTWC RTWC 24V A...

Страница 7: ...s Fig 11 Installation situation 24V M GND 24V M GND KW KR KA 24VE GNDE RT BL AT RLWC RTWC RTWC 24V AT AT 15 4 8 1 Service unit Reset button AT AT further reset button Pull cord push button Emergency s...

Страница 8: ...DE GND external RT Call button BL Status light AT Reset button KA Make contact KR Break contact KW Contact input M Service unit terminal GND Power supply 24V Power supply The external connections are...

Страница 9: ...RS 0834 USV For bridging power failures With replaceable accumulator ref no NRS AKKU 130 Reports accumulator error or power failure to the emergency signal 24V IN M GND GND 24V OUT Fig 16 UPS module r...

Страница 10: ...l unit with acoustical and visual call call suppression and call interruption for 20 s 24V M GND Fig 17 Service unit rear side 24V Power supply GND Power supply M Emergency signal terminal Call button...

Страница 11: ...20 WW Surface mounted housing for service terminal NRS DZT AP WW Deflexion pulley set NRS ULR 0834 Accumulator for UPS module NRS AKKU 130 Pull cord ZS 34 KO5S Technical data General Ambient temperat...

Отзывы: