background image

KNX 
KNX medium 

TP 1 

Commissioning mode 

S mode 

Rated voltage KNX 

DC 21 V ... 32 V SELV 

Power consumption KNX 

max. 240 mW 

Connection mode KNX 

Connection terminal on control cable 

5.2 Warranty 

We reserve the right to make technical and formal changes to the product in the interest of 
technical progress. 
We provide a warranty as provided for by law. 
Please send the unit postage-free with a description of the defect to our central customer 
service office: 

ALBRECHT JUNG GMBH & CO. KG 

Service Center 
Kupferstr. 17-19 
D-44532 Lünen 
Service-Line: +49 (0) 23 55 . 80 65 51 
Telefax: +49 (0) 23 55 . 80 61 89 
[email protected] 

General equipment 

Service-Line: +49 (0) 23 55 . 80 65 55 
Telefax: +49 (0) 23 55 . 80 62 55 
[email protected] 

KNX equipment 

Service-Line: +49 (0) 23 55 . 80 65 56 
Telefax: +49 (0) 23 55 . 80 62 55 
[email protected] 

The 

Œ

 symbol is a free trade symbol, which is solely intended for the authorities and does not 

guarantee any properties. 

ALBRECHT JUNG GMBH & CO. KG 

Volmestraße 1 
D-58579 Schalksmühle 

Telefon: +49.23 55.8 06-0 
Telefax: +49.23 55.8 06-1 89 
E-mail: [email protected] 
Internet: www.jung.de 
              www.jung-katalog.de 

7/7 

82573403 
J:0082573403 

15.05.2009 

Flush-mounted room climate interface with satellite input 

Содержание KNX 2531 UP

Страница 1: ...o longer be available For parallel connection of several drives to an output it is indispensable to observe the corresponding instructions of the manufacturers and to use a cutoff relay if necessary T...

Страница 2: ...auxiliary programs are available on our Internet website Intended purpose Switching of electrically driven Venetian blinds awnings and similar blinds for AC 230 V mains voltage Switching of electrothe...

Страница 3: ...ower supply and cover up live parts in the working environment Connecting and mounting the device DANGER When connecting the bus extensions and mains voltage wires in a shared appliance box the KNX bu...

Страница 4: ...ice in the appliance box picture 5 i In the as delivered state Inputs 1 and 2 operate the Venetian blind output Input 3 has no function Function of Inputs 1 and 2 in the as delivered state Input NO co...

Страница 5: ...e cable picture 6 picture 7 Connection of the fine wire cable o Push the terminal together on the side with the square opening and connect a fine wire cable picture 7 5 7 82573403 J 0082573403 15 05 2...

Страница 6: ...ient conditions Ambient temperature 5 45 C Storage transport temperature 25 70 C Venetian blind output Contact type Switching current AC1 3 A Minimum switching current AC 100 mA Motors 230 V 600 VA He...

Страница 7: ...Kupferstr 17 19 D 44532 L nen Service Line 49 0 23 55 80 65 51 Telefax 49 0 23 55 80 61 89 mail vka jung de General equipment Service Line 49 0 23 55 80 65 55 Telefax 49 0 23 55 80 62 55 mail vkm jun...

Отзывы: