background image

1

Safety instructions

Electrical devices may only be mounted and connected by electrically skilled
persons.

Serious injuries, fire or property damage possible. Please read and follow manual
fully.

Danger of electric shock. Always disconnect before carrying out work on the device
or load. In so doing, take all the circuit breakers into account, which support danger-
ous voltages to the device and or load.

Danger of electric shock. The sensor cable is connected to the mains voltage poten-
tial. If the sensor cable is damaged, immediately disconnect the device from the
mains by switching off all associated circuit breakers.

This manual is an integral part of the product, and must remain with the end cus-
tomer.

2

Device components

Image 1: Device components

(1)

Room temperature controller insert

(2)

Frame

(3)

Status LED

(4)

Central plate

(5)

Control knob

(6)

Adjustment rings for temperature limit

3

Intended use

Electronic temperature controller for controlling electric underfloor heating or
floor temperature conditioning systems

Control of the floor temperature in closed rooms

Mounting in appliance box with dimensions according to DIN 49073

Floor thermostat

3 / 9

82404903

16.09.2022

J0082404903

Содержание FTR231

Страница 1: ...uctions Floor thermostat Art no FTR231 16 09 2022 82404903 J0082404903 ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencenter jung...

Страница 2: ...omponents 3 3 Intended use 3 4 Product characteristics 4 5 Functional description 4 6 Operation 4 7 Information for electrically skilled persons 5 7 1 Commissioning 7 8 Technical data 8 9 Warranty 9 2...

Страница 3: ...he sensor cable is damaged immediately disconnect the device from the mains by switching off all associated circuit breakers This manual is an integral part of the product and must remain with the end...

Страница 4: ...ed Pulse width modulated control factory setting The output is not permanently actu ated but for a time period pulse width that depends on the difference between tar get and actual temperature This me...

Страница 5: ...he LED lights up or flashes in the colour magenta LED lights up magenta permanent operation is active LED flashes magenta permanent operation is inactive default setting Press the control knob briefly...

Страница 6: ...xternal temperature sensor remote sensor 8 Switching contact of central clock 9 Electric underfloor heating Connect insert 1 according to the connection diagram see figure 2 Ob serve the conductor cro...

Страница 7: ...shes green for PWM control and green blue for 2 point control Press the control knob briefly The control behaviour is changed Press the control knob for longer than one second The current control beha...

Страница 8: ...ed minimum temper ature Each notch corresponds to a change of about 2 C Turn the small red adjustment ring anticlockwise to the desired maximum tem perature The respective adjustment ring can only be...

Страница 9: ...to energy efficiency 2 FFNTC remote sensor Dimensions H 7 8 20 mm Length connecting cable 4 m can be extended to 50 m Degree of protection IP 67 9 Warranty The warranty is provided in accordance with...

Отзывы: