Jung FMR100SGWW Скачать руководство пользователя страница 5

Radio frequency

868.0 ... 868.6 MHz

Transmitting range in free field

typ. 100 m

Transmission capacity

max. 20 mW

Receiver category

2

5.2 Troubleshooting

Additional connections to transmitters or actuators are not possible.

Cause: All the memory locations in the repeater are occupied.

Disconnect connections no longer required.
or
Reset repeater to the default setting so that all received telegrams are repeated.

Despite a repeater there is no radio reception.

Cause 1: Structural conditions prevent radio reception.

Change the position of the repeater.

Cause 2: The repeater only repeats selected telegrams.

Connect radio transmitter and actuator to repeater.

Cause 3: Repeater is not supplied with voltage.

Check power supply.

Cause 4: Two repeaters are switched in sequence. The transmitter and actuator/energy sensor
are not connected to both repeaters.

Connect both the transmitter and the actuator/energy sensor with both repeaters.

Radio transmitter does not receive any feedback from the actuator

Cause: Only the radio transmitter is connected to the repeater.

Connect actuator to repeater.

5.3 Conformity

Albrecht Jung GmbH & Co. KG hereby declares that the radio system type
 Art. No. FMR100SGWW
corresponds to the directive 2014/53/EU. You can find the full article number on the device. The
complete text of the EU Declaration of Conformity is available under the Internet address:
www.jung.de/ce

5.4 Warranty

The warranty follows about the specialty store in between the legal framework as provided for
by law.

ALBRECHT JUNG GMBH & CO. KG

Volmestraße 1
58579 Schalksmühle
GERMANY

Telefon: +49 2355 806-0
Telefax: +49 2355 806-204
kundencenter@jung.de
www.jung.de

5/5

82586533
J0082586533

27.03.2017

eNet radio repeater in SCHUKO housing

Содержание FMR100SGWW

Страница 1: ...ergency stop and emergency call These instructions are an integral part of the product and must remain with the end customer 2 Device components Figure 1 Repeater 1 SCHUKO socket with increased contact protection 2 Red status LED covered 3 Prog button 3 Function Intended use Receiving and repeating eNet radio telegrams Extending the range of radio transmitters and actuators Indoor mounting in SCHU...

Страница 2: ...ctrical connection Mounting To ensure good transmission quality keep a sufficient distance from any possible sources of interference e g metallic surfaces microwave ovens hi fi and TV systems ballasts or transformers o Insert device into socket outlet 4 2 Commissioning DANGER Electrical shock when live parts are touched Electrical shocks can be fatal Before working on the device cover up live part...

Страница 3: ...peat radio telegrams from certain devices i If two repeaters are switched in sequence then connect both the transmitter and the actuator energy sensor with both repeaters During the connection operation the repeater and transmitter or actuator energy sensor must be within radio range of one another o Step A Connect repeaters 1 and 2 to the radio transmitter see Connecting repeater to radio transmi...

Страница 4: ... transmitter The repeater and radio transmitter exit the programming mode automatically Disconnecting connection to an actuator or energy sensor i All the connections to an actuator or energy sensor are disconnected o Carry out the same steps as when connecting see Connecting repeater to actuator or energy sensor The status LED 2 of the repeater and the status LED on the actuator or energy sensor ...

Страница 5: ...nce The transmitter and actuator energy sensor are not connected to both repeaters Connect both the transmitter and the actuator energy sensor with both repeaters Radio transmitter does not receive any feedback from the actuator Cause Only the radio transmitter is connected to the repeater Connect actuator to repeater 5 3 Conformity Albrecht Jung GmbH Co KG hereby declares that the radio system ty...