Jung FMAS16REG Скачать руководство пользователя страница 1

eNet radio switch/push-button actuator 1-gang, for rail mounting

eNet radio switch/push-button actuator 1-gang, for rail mounting

Art. No. : FMAS16REG

Operating instructions

1 Safety instructions

Electrical devices may only be mounted and connected by electrically skilled
persons.

Serious injuries, fire or property damage possible. Please read and follow manual fully.

Danger of electric shock. Always disconnect before carrying out work on the devise or
load. In so doing, take all the circuit breakers into account, which support dangerous
voltages to the device and or load.

Danger of electric shock. During installation and cable routing, comply with the
regulations and standards which apply for SELV circuits.

Danger of electric shock. Device is not suitable for disconnection from supply voltage.

Fire hazard! Operation exclusively with the power supplies listed under accessories

These instructions are an integral part of the product, and must remain with the end
customer.

2 Device components

Figure 1: Device components

(1) Load connection
(2) Operating mode switch
(3) Button 

Prog

(4) Status LED
(5)  Bus line connection

3 Function

Intended use

-

Switching of lighting

-

Operation with suitable eNet radio transmitters

1/12

82581723
J0082581723

23.03.2017

Содержание FMAS16REG

Страница 1: ...port dangerous voltages to the device and or load Danger of electric shock During installation and cable routing comply with the regulations and standards which apply for SELV circuits Danger of elect...

Страница 2: ...Fully encrypted radio transmission AES CCM from eNet Server software version 2 0 Update of the device software Reading of error memory Behaviour in case of bus voltage failure and return If the bus v...

Страница 3: ...k grey Power supply DC RD red Power supply Bus WH white Data cable Bus YE yellow Data cable As bus line use e g J Y St Y 2x2x0 8 o Connect the device with bus line figure 2 to the RMD reception module...

Страница 4: ...eter set with eNet server M Push button operation K Switching operation If the operating mode switch is turned from the position PC to another operating mode the parameters are set to the default sett...

Страница 5: ...place i Scene buttons must be connected separately Disconnecting connection to a radio transmitter o Carry out the same steps as when connecting see Connecting actuator to radio transmitters The statu...

Страница 6: ...out conductor sleeve 0 75 4 mm Finely stranded with conductor sleeve 0 5 2 5 mm Fitting width 36 mm 2 modules Bus line Rated voltage DC 12 V SELV Current consumption max 20 mA Connection Bus device co...

Страница 7: ...frequency can be changed using parameters The parameter Switch off delay is used for the pulse time and the parameter Switch on delay for the pause time Continuous on The output switches to continuous...

Страница 8: ...s parameter Comment The set times apply to operation using radio transmitters The relay is switched immediately when the Prog button is pressed Run on time 0 s 24 h Basic setting 0 s As soon as a run...

Страница 9: ...ff Basic setting On Blocks the output for operation using the Prog button Behaviour on voltage return On Off Last value Configured brightness Basic setting Off Defines the behaviour of the output afte...

Страница 10: ...switching state On Off Basic setting On Defines the behaviour of the output on activating the forced operation Deactivate forced operation switching state On Off Basic setting Off Defines the behaviou...

Страница 11: ...is not yet active as a light controller has not yet been implemented Switch on brightness undershoot On Off Basic setting Off Allows automatic switch on according to the brightness If the parameter is...

Страница 12: ...ungen 6 3 Accessories Power supply 12 V for rail mounting Art No NT1220REGVDC eNet master receiver for rail mounting Art No FMFK32REG eNet server for rail mounting Art No ENET SERVER 6 4 Warranty The...

Отзывы: