background image

Figure 2: Reduced range due to structural obstacles

Example of penetration of various materials:

Material

Penetration

Wood, Plaster, Plasterboard

approx. 90%

Brick, Chipboard

approx. 70%

Reinforced concrete

approx. 30%

Metal, Metal grid

approx. 10%

Rain, Snow

approx. 1-40%

Intended use

-

Motion detector for automatic switch-on of lighting depending on heat motions and ambient
brightness

-

Operation in conjunction with radio power pack and suitable radio actuators

-

Surface-mounting

i

The motion detector is not secured against tampering, and is therefore not suitable for use
in alarm systems.

Product characteristics

-

The motion detector detects heat motions caused by people, animals and inanimate
objects.

-

Sensitivity can be set

-

Brightness value can be set

-

Detection area can be limited using cover plate

-

Battery-powered device

Response when actuators switched on

-

A dimmer actuator which is switched on switches on to the stored switch-on brightness
when a motion detector telegram is received. When the run-on time elapses, the brightness
previously set manually is restored.

-

A switched-on radio switch actuator remains switched on when a motion detector telegram
is received and after the run-on time elapses.

2/8

32552843
J0082552843

16.08.2016

Radio Management 

Radio automatic switch 180°

Содержание FAS180 Series

Страница 1: ...dren If button cells are swallowed get medical help immediately Risk of explosion Do not throw batteries into fire Risk of explosion Do not recharge batteries These instructions are an integral part of the product and must remain with the end customer 2 Device components Figure 1 1 Base plate 2 Frame 3 Radio motion detector 4 Cover 3 Function System information By statute the transmitting power th...

Страница 2: ...re not suitable for use in alarm systems Product characteristics The motion detector detects heat motions caused by people animals and inanimate objects Sensitivity can be set Brightness value can be set Detection area can be limited using cover plate Battery powered device Response when actuators switched on A dimmer actuator which is switched on switches on to the stored switch on brightness whe...

Страница 3: ...e of the detection field refer to an installation height of 1 10 m The nominal range varies for different installation heights i The orientation of the upper lens plate does not limit the detection field in space Therefore in some circumstances even motions outside of the specified detection field may trigger switching operations Several basic principles must be taken into account when selecting t...

Страница 4: ... in repeated switch on Fitting the motion detector i Before fitting first perform the teaching procedures and adjustments if necessary see sections Teaching motion detector in radio receiver and Setting the sensitivity and brightness setpoint o Inset battery if necessary see section Changing the battery The cover plate for limiting the detection area is preinstalled at the factory In order to moni...

Страница 5: ...7 Figure 8 Insert battery i Keep contacts of batteries and device free of grease o Apply new battery to the positive contact of the battery holder Observe correct polarity the positive pole of the battery must be at the top figure 8 o Press gently on battery to snap it in o Carefully fit motion detector with frame on the guide pins of the base plate The battery holder must fit in the corresponding...

Страница 6: ... mode for approx 10 minutes This is displayed by rapid flashing of the LED In this mode the motion detector evaluates motions regardless of the brightness Every telegram transmitted here can be taught in the radio receiver o Test the detection area by walking over it and mount push on cover if necessary see Limiting the detection area Each telegram transmitted switches the receiver on for approx 2...

Страница 7: ...over plate 10 can be used to mask unwanted detection areas figure 10 The cover plate can cover up the left 8 or right half 9 of the detection fields 90 in each case i Always use the entire cover plate Cutting out the cover plate to a smaller angle will result in malfunctions o Fit cover plate on sensor window 5 Appendix Remove empty batteries immediately and dispose of in an environmentally friend...

Страница 8: ...sitivity and brightness setpoint Cause 2 the motion detector is in the walking test teaching mode Wait 2 minutes with no motion in the detection field otherwise 10 minutes After that the walking test teaching mode is exited automatically Cause 3 There is a continuous motion in the detection field of the motion detector Eliminate cause of the continuous motion 5 3 Conformity Albrecht Jung GmbH Co K...