Temperature Management
Hygrostat
Ref.-no.:
..5201
HYG..
Install the hygrostat in a place shielded from direct sunlight, draughts and
heat radiation from nearby electrical appliances as, for instance, cooking
ranges or refrigerators.
Do not install the hygrostat above or in the vicinity of heating appliances.
If possible, install the hygrostat only on a base behaving neutrally in the
presence of moisture. Hygroscopic material like plasterboard can
influence the control characteristics.
For installation installation in bathrooms, laundry rooms, etc.: observe the
safety distances in acc. with IEC 60364-7-701.
Fitting height: approx. 1.5 m
Installation in a flush-mounting box in acc. with DIN 49073.
•
Connect the insert (Fig. 2).
•
To set a fixed humidity value: turn the setscrew on the rear of the
attachment module to
60 %
(Fig. 3).
•
To activate the control knob function: turn the setscrew on the rear
of the attachment module fully to the left to
20-95 %
(Fig. 3).
Fig. 3: Setscrew for setpoint selection
•
Place the decorative frame on the insert.
•
Plug the attachment onto the insert observing the correct position
(Fig. 4).
Fig. 4: Fitting of the attachment
6