0024015020 12.10.2012

Information for electrically skilled persons
Installation and electrical connection

DANGER!

Electric shock from touching live parts in the installation environment.

An electric shock can be fatal.

Before working on the device, disconnect the power and cover live parts in the area!

Snapping on the adapter frame

An adapter frame is required depending on the switch range.

The adapter frame for the series LS is pre-mounted.

•  Snap adapter frame (3) in the right orientation from the front onto the module (8) (Figure 2). Observe the label „TOP“.

Connection

 

Attention!

Connect the push-button sensor module exclusively to the universal stations.

Installing and connecting the device

(8)

(13)

(4)

(5)

(5)

(11)

(12)

(8)

(10)

(9)

Bild 2:  Installation with expansion module

(9)   Connecting cable TSEM

(10) Plug-in position

(11) Push-button sensor expansion module

(12) Frame

(13) Double supporting ring

Supporting ring side A for A range, CD range

and flat design. 

Supporting ring side B for LS range.

When using the push-button sensor expansion module (Figure 2): vertical installation is preferred. Use the double supporting ring (13). For 

installation to a flush-mounted box only, countersink the lower screws in the wall, e.g. with bore ø 6 x 10 mm. Use supporting ring as template.

DANGER!

When installing with 230 V devices under a common cover, e.g. socket outlets, there is a danger of electric shock in the event 

of an error!

An electric shock can be fatal.

Do not install any 230 V devices in combination with a push-button sensor expansion module under a common cover!

•  Install supporting ring (1) or (13) in the right orientation on an appliance box. Observe the label „TOP“; label A or B forwards.  

Use only the supplied box screws (8).

•  Insert frame (2) onto the supporting ring.

•  Preferred installation position of push-button sensor expansion module (15) is below.  

Guide connecting cable (16) between supporting ring and intermediate web.

•   Push-button sensor expansion module: insert connecting cable (16) in the right orientation in the plug-in position (17) in the push-button 

sensor module. 

 

Do not pinch the connecting cable.

•  Connect push-button sensor module (4) with connecting terminal (7) to the station and insert onto the supporting ring.

•  Fasten the push-button sensor module(s) to the supporting ring using the enclosed plastic screws (5).  

Only tighten the plastic screws lightly.

Содержание 4008 TSM

Страница 1: ...red Buttons can be configured corresponding to the cover kit Programming without additional aids Free assignment of the buttons to the channels Red LED as status indicator can be switched off Blue orientation light can be switched off Feedback of switching states on all connected push button sensor modules and sensor modules Up to 4 push button sensor modules with up to 4 push button sensor expans...

Страница 2: ...referred Use the double supporting ring 13 For installation to a flush mounted box only countersink the lower screws in the wall e g with bore ø 6 x 10 mm Use supporting ring as template DANGER When installing with 230 V devices under a common cover e g socket outlets there is a danger of electric shock in the event of an error An electric shock can be fatal Do not install any 230 V devices in com...

Страница 3: ...ule is operated with a push button sensor expansion module on a single station the push button sensor expan sion module does not have any function in the state as delivered 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Bild3 Button assignment in state as delivered without and with push button sensor expansion module Grouping 1 16 13 16 1 4 1 14 3 16 1 2 14 13 15 3 4 16 1 1 3 9 14 16 6 2 5...

Страница 4: ...ns In the state as delivered all channels respond to the central function Preliminary remark to light scene button 3 ⓘ ⓘ Before setting the light scene the station must be set through button 6 Switching several outputs with one button Switching states are assigned to the outputs 4 light scenes per control point are available Preliminary remark to status LED on off button 4 The button next to the r...

Страница 5: ...econds LEDs 1 4 6 light up Make additional settings or end programming End programming press and hold button 16 approx 3 seconds Operating level is active Button 2 Setting or changing the central function When assigning the central function button 1 for central ON or button 2 for central OFF is selected then the buttons which should switch the central function It is also possible to assign only ce...

Страница 6: ...th channel 1 on and channel 2 off For light scenes the following settings for output 1 apply LED channel 1 LED channel 2 Light ON ON Current status is retained LED flashes slowly ON Switching on brightness LED flashes quickly ON Maximum brightness ON LED flashes quickly Minimum brightness ON OFF off ⓘ ⓘ During display of the light scene the outputs at the stations correspondingly switch with delay...

Страница 7: ...normal mode Press micro buttons 12 9 7 9 in sequence All LEDs flash 2x Press micro buttons 12 9 7 9 in sequence once again All LEDs flash 2x The state as delivered has been restored Push button sensor module is ready for operation Installing buttons The buttons are available as a complete button set Individual buttons or the complete button set can be replaced using buttons with sym bols ⓘ ⓘ The i...

Страница 8: ...ty class III Ambient temperature 5 45 C Storage temperature 25 70 C Connection type connection terminal Cable length max 100 m Cable type J Y St 4 2 x 2 x 0 8 Help in case of problems Push button sensor module does not respond Two stations are connected in parallel Device address of the second station was not converted Change device address Push button sensor module does not display the switching ...

Отзывы: