Jung 3361-1AL-01 Скачать руководство пользователя страница 1

Presence detector standard

Art. No. : 3361WW-01

Presence detector standard

Art. No. : 3361AL-01

Presende detector Universal

Art. No. : 3361-1WW-01

Presende detector Universal

Art. No. : 3361-1AL-01

Operating instructions

1 Safety instructions

Presence detector

1/12

82585625
J0082585625

04.12.2017

Содержание 3361-1AL-01

Страница 1: ...01 Presence detector standard Art No 3361AL 01 Presende detector Universal Art No 3361 1WW 01 Presende detector Universal Art No 3361 1AL 01 Operating instructions 1 Safety instructions Presence detec...

Страница 2: ...ce is a product of the KNX system and complies with the KNX directives Detailed technical knowledge obtained in KNX training courses is a prerequisite to proper understanding The function of this devi...

Страница 3: ...switching on the motion detection works brightness independently Alert operation Brightness independent detection of motions in the detection field Switch on After detection of an adjustable number of...

Страница 4: ...ress button Manually change settings with IR remote control If enabled individual settings for function block 1 can be changed during operation using a remote control Sensitivity o Increase sensitivit...

Страница 5: ...tion for electrically skilled persons 5 1 Mounting and electrical connection Detection field and range Figure 2 Tangential and radial direction of motion 5 12 Presence detector 82585625 J0082585625 04...

Страница 6: ...ation height 1 2 3 4 7 20 ft 47 60 ft 37 70 ft 26 30 ft 19 70 ft 8 20 ft 54 10 ft 42 70 ft 32 80 ft 23 00 ft 9 80 ft 65 60 ft 52 50 ft 39 40 ft 26 30 ft 11 50 ft 75 50 ft 60 70 ft 45 90 ft 29 50 ft 13...

Страница 7: ...Area I cut out approx 24 60 ft Areas I II cut out approx 39 40 ft without push on cover approx 65 60 ft o Pull off push on cover o Using scissors cut out push on cover along the marked lines as requi...

Страница 8: ...Figure 5 Detection field areas A B and C installation height 8 20 ft 8 12 Presence detector 82585625 J0082585625 04 12 2017...

Страница 9: ...cal wall boxes flush mounted i Wall boxes must be ordered separately o Wall boxes for solid walls have to be placed flush to the wall plaster o Hollow wall boxes were placed by circular cutter A hole...

Страница 10: ...Press the programming button 7 The programming LED 5 in the sensor window lights up o Assign physical address The programming LED goes out o Write the physical address on the device label o Load the a...

Страница 11: ...n block active Change function block switch over Cause 2 Brightness threshold set is too low Increase the brightness threshold with the remote control or parameter setting Light switches on despite su...

Страница 12: ...eshold with the remote control or parameter setting Light does not switch on or switches on too late despite motion in the detection field Cause 1 Device is set for alert operation and does not evalua...

Отзывы: