LB management

Display standard for room temperature control

ƛ

Ƽ

 and YES or No appear in the display.

The parameters can be confirmed (

ƨ

 button) or changed (– or + button) as described in the

Commissioning section.

After value changes, the device will start with the saved setpoint values.

Saving current time as switching time, quick programming

Switching times can also be saved without calling up the programming menu. The current time
is saved as the switching time for Mo-Fr and Sa-So.

Quick programming overwrites the existing ECO or comfort temperature in the first
memory area. The switching times from memory areas 2 and 3 are deactivated.

Press and hold the 

ƨ

 button and additionally press the – button for the ECO temperature

or the + button for the comfort temperature for more than 1 second.
SAVE appears in the display. The current time is saved as the new switching time for the
ECO or comfort temperature.

Display: setpoint temperature, actual temperature or current time

After commissioning, the device indicates the setpoint temperature and switches off the display
after 2 minutes without any operation. Alternatively, the actual temperature or current time can
be displayed. 
The display can also remain switched on continuously.

Press the 

ƨ

 and 

Ƙ

 buttons simultaneously for longer than 10 seconds.

A countdown runs in the display. When "0" is reached, the actual temperature is shown in
the display.

The active temperature sensor is shown in the display when the actual temperature indic-
ation is selected.

ƻ

 or 

ƻ

 and 

ƺ

: The measured value is provided by the internal sensor.

ƺ

: The measured value is provided by the remote sensor connected to the insert.

Press the 

ƨ

 and 

Ƙ

 buttons simultaneously again for more than 10 seconds.

A countdown runs in the display. When "0" is reached, the current time is displayed.

Use the same operating step to switch back to setpoint temperature display.

Press the 

ƨ

 and 

Ƨ

 buttons simultaneously for longer than 10 seconds.

A countdown runs in the display. When "0" is reached, the display is switched on continu-
ously.

Use the same operating step to switch the display off again after 2 minutes. The display
briefly turns dark to indicate confirmation.

In setpoint or actual temperature display mode, the 

ƨ

 or 

Ƨ

 button can be pressed for more

than 1 second to display the current time as long as the button is actuated.

Resetting the cover to the default setting

Press the 

Ƨ

 and 

Ƙ

 buttons simultaneously for 10 seconds.

A countdown runs in the display. The reset is performed with "0".

The default setting is restored. The year flashes in the display and the device must be re-
commissioned (see Commissioning section).

9

Information for electrically skilled persons

This device includes an integrated battery. At the end of its useful life, dispose of the
device together with the battery in accordance with the environmental regulations. Do
not throw device into household waste. Consult your local authorities about

environmentally friendly disposal. According to statutory provisions, the end consumer is
obligated to return the device.

8 / 10

32401503

19.05.2020

J0082401503

Содержание 1790D Series

Страница 1: ...to the device and or load These instructions are an integral part of the product and must remain with the end customer 2 Device components Figure 1 Display and operating area 1 Setpoint temperature a...

Страница 2: ...tion PWM or two point Valve protection function once a week opening and closing of valve on Saturdays at 11 a m Interrupts the heating process after 60 minutes for 5 minutes Display switch off after 2...

Страница 3: ...le time is 15 minutes Valve adaptation This parameter is used to adapt to the electrothermal valve drives There are drives that are either open deenergised open setting NO or closed deenergised closed...

Страница 4: ...ata listed in the table Briefly press the or button to change values or toggle between YES No A long press of the or button accelerates value changes Press the button to go back in the menu Press the...

Страница 5: ...l mode in automatic mode it is retained until the next switching time is reached In cooling mode the or buttons cannot be used to change the setpoint temperature If the display is switched off or has...

Страница 6: ...he programming menu Navigate through the menu with the or button and confirm the selection with the button Activating deactivating the operating lock Three memory areas for comfort and ECO temperature...

Страница 7: ...ly for the weekday blocks Mo Fr and Sa Su each The menu is exited upon saving the last time setting Set the clock to deactivate individual switching times After one minute without any operation the me...

Страница 8: ...n the display when the actual temperature indic ation is selected or and The measured value is provided by the internal sensor The measured value is provided by the remote sensor connected to the inse...

Страница 9: ...Overview of button combinations Button combination Length of button press Display Reading What happens and Longer than one second is shown or hidden Button lockout is activated or deac tivated and Lon...

Страница 10: ...standard for room temperature control ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencenter jung de www jung de 10 10 32401503 1...

Отзывы: