LB management
Speed regulator
5
Information for electrically skilled persons
5.1 Fitting and electrical connection
DANGER!
Mortal danger of electric shock.
Disconnect the device. Cover up live parts.
Fitting and electrical connection
L
1
N
16 A
AC 230 V ~
L
M
L
I
max
= 1,8 A
N
1
1
N
L
~
(4)
(2)
(1)
(5)
(6)
(3)
Figure 1: Connection diagram with optional extensions
(1)
Button Test
(2)
LED display
(3)
Rotary axle
(4)
3-wire rotary extension
(5)
2-wire extension
(6)
Push-button, NO contact
The connection of a central extension is not possible.
Operation without neutral conductor possible.
Only connect illuminated push buttons if they have a separate N terminal.
Precondition: The maximum motor current (I
max
) must not exceed the switching current of 1.8 A.
2 / 5
82404703
01.04.2021
J0082404703