Implementing a wind alarm
Wind sensors serve to protect a Venetian blind from being destroyed by a strong
wind. The Venetian blind is moved to a safe end position and locked there until the
wind drops below the set threshold value.
Image 6: Connection example of wind sensor
■
Connect the wind sensor (8) according to the connection example
(see figure 6). The wind alarm is implemented via extension input 2.
In order to use the wind alarm for all external Venetian blinds of a building, the
wind sensor must be connected to extension unit input 2 of the master control.
As long as an Up command is active on extension unit input 2, the Venetian
blind cannot be operated either manually or automatically.
Resetting overload switch-off
If the electronic overload cut-off has triggered, disconnect the device from the mains
for a short time.
6
Technical data
Rated voltage
AC 230 V ~
Mains frequency
50 / 60 Hz
Standby power: 0.1…0.5 W, depending on the cover
Ambient temperature
-5 ... +45 °C
Storage/transport temperature
-20 ... +70 °C
Running time
approx. 120 s
Connected load
Motors
700 W
7
Warranty
The warranty is provided in accordance with statutory requirements via the specialist
trade.
Universal blinds insert
8 / 9
82595633
19.08.2022
J0082595633