Light Management
Tronic switching insert
Ref.-no.:1254TSE
3. Installation
Instructions
Install Tronic switching insert (1) in a connection box as per DIN 49073
(Fig. A).
).
Fig. A
The terminals of the Tronic switching insert must be down. Use the Tronic
switching insert only in combination with an attachment. Plug attachment
(2)onto Tronic switching insert (3)together with frame (1). The electrical
contact is established through plug contacts (4). Mains failures of longer
than 1 sec. will lead to turning off the Tronic switching insert.
4. Short-Circuit
Protection
Switching off with automatic restarting after short-circuit elimination within
7 sec. For longer short-circuits, permanent switching off until a manual
restart is triggered when a shortstroke key is used.
5. Overtemperature
Protection
Switching off in case of excessively high ambient temperature. After
cooling down, the device must be restarted.
6. Connection
Connect as shown in Fig. B.
Tronic switching insert
g
Load
j
Fig. B
Observe the maximum connected load and the load
details as set out in the Technical Specifications.
2