Bluetooth Weight Scale 

JPD-700A 

User Manual 

 

 

 

Shenzhen Jumper Medical Equipment Co., Ltd.   

 

Date  of  compilation:  April  2017  Version:  A/0 

  Please read this User Manual carefully before using the product. 

Содержание JPD-700A

Страница 1: ...Bluetooth Weight Scale JPD 700A User Manual Shenzhen Jumper Medical Equipment Co Ltd Date of compilation April 2017 Version A 0 Please read this User Manual carefully before using the product...

Страница 2: ...ill be transmitted to the phone synchronously This means that users can check their weight anytime by opening the APP for weight management on their phone This product helps users to develop good habi...

Страница 3: ...t Structural Components and Display 3 Unit Conversion 4 Instructions for Use 5 11 FAQs on Weight Measurement 12 Troubleshooting 13 Safety Caution 14 Description of Marks and Symbols 15 Cleaning and Ma...

Страница 4: ...n accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment...

Страница 5: ...ait until it turns on when the LED displays digits Then step off the scale and stand back on in an upright and steady position when the LED displays zero See the picture below for the correct standing...

Страница 6: ...Product Structural Components and Display 3 1 Product Structural Components 2 Display Interface Digital display Bluetooth lb kg Weight units LED Display Sensor Measuring Surface Battery Cover...

Страница 7: ...off and adjust the gear toggle switch The units available are kg lb and jin 500g from left to right When the switch is placed at one of the gears the displayed unit automatically switches to the corre...

Страница 8: ...hard and flat surface When replacing the batteries please install three AAA batteries based on the position of positive and negative poles alkaline AAA batteries are preferred 2 Download the APP clien...

Страница 9: ...Instructions for Use 6 3 User registration and login Open JUMPER Health complete the user registration and login as instructed Enter your nickname gender date of birth and height as instructed...

Страница 10: ...Instructions for Use 7 4 Enter the Monitoring Page After the registration and login click Detection at the bottom of the page and then choose Weight to enter the weight monitoring module...

Страница 11: ...uetooth after receiving the prompt in the weight monitoring module and then stand on the scale When the data stabilizes your mobile phone will display the measured data This means that the Bluetooth c...

Страница 12: ...e APP is saved automatically and the user s identity is authenticated based on the account Therefore you will need to register for a user account and fill in your nickname gender date of birth and hei...

Страница 13: ...anding on the scale for measurement Stand on the scale surface to measure your weight The measured data will automatically display on the mobile phone and your BMI will automatically be calculated bas...

Страница 14: ...Instructions for Use 11 7 Checking the record Check the record by clicking Record The daily measured data is automatically recorded in the tendency chart so users may check their weight anytime...

Страница 15: ...en ground or when the user stands in different positions on the scale Thus when measuring your weight please place the scale on a hard and flat surface try to stand in the same position every time and...

Страница 16: ...d returns to zero The minimum weight for turning on the scale is 4 5kg The mobile APP is not synced with the data The mobile Bluetooth is not turned on Properly connect the mobile phone to the scale I...

Страница 17: ...r use is prohibited 2 When the product stops working or expires please follow the regulations of the local environmental protection authorities in terms of the disposal of waste and batteries and disp...

Страница 18: ...and Signs 15 Sign Description Attention Refer to the user manual Waste electrical materials should be sent to a dedicated collection point for recycling Bluetooth Recyclable Environmentally friendly u...

Страница 19: ...e indoors when it is not being used 2 As this product is a precision instrument please operate it with caution and be careful to avoid shaking dropping or vibrating the product 3 The product must be r...

Страница 20: ...on with a minimum weight of 4 5kg for turning it on and auto power off in 10s with no measurement 8 Overload display low voltage display 9 Power supply three AAA batteries 10 Dimensions 375mm 301mm 2...

Страница 21: ...Technical Specifications 18 14 Bluetooth Technical Parameters Frequency Range 2402 2480MHz Modulation Type GFSK Frequency Tolerance 20ppm Number of channel 40CH Spurious Emission Limit...

Страница 22: ...14 53 EU Note The worst carrier frequency is 2402MHz and use a PCB antenna This device operates in 2402 2480MHz There are no restrictions of use in EU country RF Exposure This equipment complies with...

Страница 23: ...e device excluding its handset and users Product Name Bluetooth Weight Scale FCC ID 2ADYL JPD700A Manufacturer Shenzhen Jumper Medical Equipment Co Ltd Address D Building No 71 Xintian Road Fuyong Str...