background image

   

 

 

Product Information 

Product Name: 

Fetal Heart Detector 

Model: JPD-100S 

Manufacturer:

 JUMPER MEDICAL EQUIPMENT CO., LTD 

Add:

 6th Floor, No.6 Bldg., Nanshui Industry Village,5th Industry 

Rd.,Shenzhen 518067 P.R.China 

Copyright 

Copyright 2009.All rights reserved. 

Statement 

Jumper Medical Equipment Co., Ltd owns the copyright of this non-public 

instruction book.   

Without written authorization from Jumper Medical Equipment Co., Ltd, 

any individual or organization shall not copy, modify or translate this 

book.   

All contents described in this book are consistent with the actual situation 

of the related product.   

Jumper Medical Equipment Co., Ltd has right to revise all contents of this 

book if needed, without prior notice.   

Jumper Medical Equipment Co., Ltd reserves the right of final 

interpretation of this book.   

"JUMPER" and "ANGELSOUNDS" are the registered trademarks of 

Jumper Medical Equipment Co., Ltd. 

                                                                                               

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание AngelSounds JPD-100S

Страница 1: ...PER MEDICAL EQUIPMENT CO LTD 6th Floor No 6 Bldg Nanshui Industry Village 5th Industry Rd Shenzhen 518067 P R China Fetal Heart Detector JPD 100S INSTRUCTION MANUAL Manual Ver 1 0 Issuing Date 2009 11...

Страница 2: ...tion book Without written authorization from Jumper Medical Equipment Co Ltd any individual or organization shall not copy modify or translate this book All contents described in this book are consist...

Страница 3: ...bsorption and reflection from structures objects and people TABLE OF CONTENTS SECTION 1 INTRODUCTION 1 1 OVERVIEW 1 2 PRODUCT DESCRIPTION 1 1 3 OPERATING PRINCIPLE 1 SECTION 2 SAFETY GUIDANCE 2 2 1 IN...

Страница 4: ...retically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in whi...

Страница 5: ...ith the controls and how to use the product properly before operating the product CAUTION It should not be used in life supporting or life sustaining applications 1 2 PRODUCT DESCRIPTION The product i...

Страница 6: ...l Heart Detector needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided for in the ACCOMPANYING DOCUMENTS Portable and mobile...

Страница 7: ...eath CAUTION This alert identifies hazards that may cause minor personal injury product damage or property damage 2 5 SAFETY ALERT DESCRIPTIONS The following is a list of product safety alerts that ap...

Страница 8: ...damage to the metal connectors CAUTION Environment of use The product is designed for indoor use Operator must confirm that the environment of use meets the required operating environmental specificat...

Страница 9: ...P R China Tel 86 755 26696279 Fax 86 755 26852025 Web site http www jumper medical com Wellkang Ltd Suite B 29Harley Street LONDON W1G9QR U K 5 2 6 SYMBOL DESCRIPTIONS The following symbols may appear...

Страница 10: ...leaning solution on the surface of the device Wipe the surface of sensor of transducer with 70 ethanol or alcohol self air dry or clean with a clean dry cloth 4 6 DISINFECTIONS Cleaning the unit surfa...

Страница 11: ...ipe the transducer body with soft cloth to remove any remaining coupling gel Clean with soap only 4 5 4 Wring any excess moisture from the cloth before cleaning 4 5 5 Avoid pouring fluids on the devic...

Страница 12: ...cables as described in the Section 5 Broken parts cracks damage or extreme wear broken or bent connectors and pins after bending and flexing the cable Replace cable if any abnormalities are found Exa...

Страница 13: ...Section 5 for temperature specifications The product requires no calibration 4 3 VISUAL INSPECTION The product and its accessories should be carefully inspected prior to installation once every 12 mon...

Страница 14: ...d Generally the site of heart of fetus is 1 3 below of navel line at its earlier stage it then moves upward with increasing of gestational period and the site of heart of fetus will be a little deviat...