Once the cable/clamp set is connected to the unit, the jump starting readiness
indicator LED (located next to the cable port) will flash green.
5. Turn ignition off before making any vehicle connections.
6. Clamp the positive (red +) clamp to the positive terminal on the vehicle
battery (for negative ground system), or an alternate vehicle starting point as
recommended by vehicle manufacturer.
7. Clamp the negative (black, –) clamp to the a vehicle ground (unpainted portion
of the chassis or non-moving metal engine part). Never connect to the fuel line,
fuel injector or carburetor as the engine ground.
Note:
Many vehicles feature alternate starting points, away from the battery.
Always use the alternate starting points whenever available.
Note:
Make sure the cables are not in the path of moving engine parts
(belts, fans, etc.).
8. Upon making a vehicle connection, the jump starting readiness indicator LED
will continue to flash green for a moment as it senses the parameters of the
new connection and then should light solid green, indicating a proper battery
connection has been made.
8a. If the jump starting readiness indicator LED lights solid red after the vehicle
connection has been made, this indicates a reverse connection. Disconnect
from vehicle immediately and correct the issue.
8b. If the jump starting readiness indicator LED continues to flash green after the
vehicle connection has been made, this indicates that the vehicle’s battery is
too low to allow the unit to activate (<1.0V) or a potential shorted connection.
Disconnect from vehicle and determine the cause of the issue before
proceeding.
Note:
Before moving to the steps outlined below, please note that activating the
override feature removes all safety from the unit – it is critical that you check all
connections and verify that the only issue is a totally dead battery.
If you check that all connections are correct and that the problem is a totally
dead battery, you can override this safety feature by pressing and holding
the override button for over 3 seconds but less than 6 seconds. A successful
override is the jump starting readiness indicator LED lighting solid green.
9. Start the vehicle (turn on the vehicle ignition).
Note:
If the vehicle doesn’t start within 6 seconds, let the unit cool for 3
minutes before attempting to start the vehicle again or you may damage the
unit.
Note:
During very cold conditions, the unit may not start on the first attempt.
We suggest attempting to start a second or third time, as the starting attempt
will warm the internal battery and improve your starting chances.
Note:
Do not attempt to jump start after four attempts – either the unit does not
have sufficient power to start the vehicle or there is a more extensive problem
with the vehicle than simply a depleted battery.