30
4 Setup program
Please note that the range-start values are related to the range
span. If the range limits are modified, the setup program will moni-
tor the entry and come up with an error message.
range span =
range end - range start
The following screenshot shows such an incorrect entry:
NOTE!
Adjustable transmitters
Adjustable transmitters (basic type extension 880 or 990)
must be readjusted after a change in the measuring range.
Please follow the instructions in the setup program.
v
Chapter 4.8 “Calibrating the range”
Configurable transmitters
When working with configurable transmitters (basic types
extensions 881 or 991) the measuring range can be
changed in a digital manner - without a new adjustment.