![JUMO 709061/8-01-020 Скачать руководство пользователя страница 48](http://html.mh-extra.com/html/jumo/709061-8-01-020/709061-8-01-020_operating-manual_2031101048.webp)
4 Operation
46
V1.04/EN/00561071 [Thyristor Power Switch TYA 201]
4.1.1 Display and control elements
and
can be used to view the current measured values such as cur-
rents, actual voltage values, load resistance setpoint value, device tempera-
ture, and power.
This information is also displayed in the diagnosis window for the setup pro-
gram.
v
4.1.2 Appearance of measured values
Overview of
measured val-
ues
At this level, the description of the measured value is displayed in the top line,
and the numerical value together with the unit is displayed in the middle.
The info line shows the selected input (with terminal designation), the active
subordinate control loop, and the operating mode.
It is also used to display temporary states (e.g. error messages).
v
Chapter 8 "Error messages and alarms"
Legend
Comment
Diagram
1
The Power LED (green) lights up permanently when the voltage
supply is connected.
Flashes at regular intervals if the display lighting is switched off.
v
Chapter 9 "What to do, if ..."
2
Display (96 x 64 pixels) with white background lighting. The in-
formation line at the bottom of the display shows the current
settings and error messages.
3
The Fuse LED (red) lights up if the semiconductor fuse is defec-
tive
4
K1 LED (yellow) fault indicator
5
Keys:
Increase value / previous parameter
Decrease value / next parameter
Cancel / one level back
Programming / one level forward
6
USB setup interface
7
Spring clip to release the plastic housing
v
Chapter 8.2 "Replacing a defective semiconductor
fuse"
(1)
(2)
(3)
(4)
(5)
(7)
(6)
Designation
Measured value
Info line or error
Содержание 709061/8-01-020
Страница 16: ...1 Introduction 14 V1 04 EN 00561071 Thyristor Power Switch TYA 201 ...
Страница 22: ...2 Mounting 20 V1 04 EN 00561071 Thyristor Power Switch TYA 201 TYA201 100A TYA201 150 200A ...
Страница 23: ...V1 04 EN 00561071 Thyristor Power Switch TYA 201 21 2 Mounting TYA201 250A ...
Страница 46: ...3 Electrical connection 44 V1 04 EN 00561071 Thyristor Power Switch TYA 201 ...
Страница 56: ...4 Operation 54 V1 04 EN 00561071 Thyristor Power Switch TYA 201 ...
Страница 78: ...5 Configuration 76 V1 04 EN 00561071 Thyristor Power Switch TYA 201 ...
Страница 96: ...6 Special device functions 94 V1 04 EN 00561071 Thyristor Power Switch TYA 201 ...
Страница 112: ...8 Error messages and alarms 110 V1 04 EN 00561071 Thyristor Power Switch TYA 201 ...
Страница 120: ...10 Technical data 118 V1 04 EN 00561071 Thyristor Power Switch TYA 201 ...
Страница 124: ...11 Certificates 122 V1 04 EN 00561071 Thyristor Power Switch TYA 201 ...