5 Configuration
60
V1.00/EN/00741192/2021-03-30 [IPC 300]
5.1.9
Analog output
Different internal values can be output as a standard signal at the analog out-
put.
5.1.10 RS422/485
Interface parameters for RS422/485 (see interface description)
Value / settings
Description
Signal type
This setting specifies the standard signal that should be out-
put.
Switched off
Output does not emit signal.
0 to 20 mA
Output emits the "Value to be output" in the form of a current
signal.
4 to 20 mA
0 to 10 V
Output emits the "Value to be output" in the form of a voltage
signal.
2 to 10 V
0 to 5 V
1 to 5 V
Value to be output
This setting involves the selection of the value that should be
output at the analog output.
Load voltage
Example:
The load voltage can vary between 0 and 380 V depending on
the device type.
As the signal range is set per default to 0 to 9999.9, the end
value must be adjusted to 380.0 to make use of the full signal
range.
Note:
Load voltage
2
= load voltage squared
Load current
2
= load current squared
Load voltage
2
Load current
Load current
2
Power (in W)
Power (in kW)
Load resistance
DC intermediate cir-
cuit voltage
Device temperature
Setpoint value
Signal range start
value
0 to 9999.9
Lower limit for the "Value to be output"
Signal range end
value
0 to 9999.9
Upper limit for the "Value to be output"
k
/ bold = default setting
Value / settings
Description
Baud rate
9600
19200
38400
Data format
8-1-none
Data bits-stop bits-parity check
8-1-odd
8-1-even
8-2-none
Device address
0 to 1 to 255
According to Modbus specification, the address 0 is actually
not permitted. In the IPC 300 it is used to switch off the signal-
ing of a bus error.
Therefore if the power controller has an RS422/485 interface,
and this is not connected to an active bus, you can suppress
the "bus error" error message by changing the address to 0.
Содержание 709051
Страница 8: ...8 V1 00 EN 00741192 2021 03 30 IPC 300 Contents...
Страница 24: ...2 Mounting 24 V1 00 EN 00741192 2021 03 30 IPC 300 2 4 Dimensions 2 4 1 Type 709051 X XX 070 or 709051 X XX 100...
Страница 26: ...2 Mounting 26 V1 00 EN 00741192 2021 03 30 IPC 300...
Страница 48: ...4 Operation 48 V1 00 EN 00741192 2021 03 30 IPC 300...
Страница 62: ...5 Configuration 62 V1 00 EN 00741192 2021 03 30 IPC 300...
Страница 76: ...6 Special device functions 76 V1 00 EN 00741192 2021 03 30 IPC 300...
Страница 84: ...8 Error messages and alarms 84 V1 00 EN 00741192 2021 03 30 IPC 300...
Страница 90: ...10 Technical data 90 V1 00 EN 00741192 2021 03 30 IPC 300...
Страница 91: ...V1 00 EN 00741192 2021 03 30 IPC 300 91 11 Certificate 11 1 China RoHS...