ENGLISH
21
ENGLISH
Please read these instructions carefully before use!
SAFETY INSTRUCTION
Before installation
Connection to the existing circulation system may only be carried out by an authorised specialist.
Do not connect the product to the mains supply before pipes have been routed and the system
interconnected.
The units are heavy and aluminium chips/sharp edges can cause cuts on the hands. Lift with your
legs, not your back. Wear gloves during assembly.
Exercise care when removing waste and remnants from the installation from pipes and systems
prior to starting the system.
Never carry out the installation or service measures on the unit in the rain or high humidity.
Read all the instructions and assembly instructions before assembly.
Filters with non-return valves that can be cleaned must be installed on the incoming water pipe and
by the pump.
Elecrical safety
New installation and extensions to existing systems must always be performed by a qualified electrician.
If you have the necessary experience and knowledge, you may replace switches and wall sockets, fit
plugs, extension cords and lamp holders. If not, you should contact an electrician. Improper installation
may result in electric shock or fire.
IMPORTANT!
The system must be connected to an earthed mains supply (230 VAC, 50 Hz, 16 A), with a residual
current device with a maximum tripping current of 30 mA and overvoltage protection.
Heat pumps take their energy from the outdoor air and the output drops when the outdoor
temperature drops.
Never poke your fingers or objects inside the unit when the system is running. Risk of personal
injury and/or damage to property.
Never pour water over the unit. Never cover the unit, partly or fully – risk of overheating.
If the unit stops or shuts down, wait 3 minutes before restarting the unit.
TECHNICAL DATA
Heat output
kW
8.8
Refrigerant, quantity
kg
R410A, 1.7 kg
Power consumption
kW
1.7
Fan speed
rpm
850
Water pressure drop
kPa
10
Noise level
dB(A)
52
Water connection
inch
2
Net weight
kg
76