– 49 –
Error
Code
Error description
Fault Cause
Solution
E023 X axis driver software over-
current
1. The parameters are incorrect
2. The motor is stuck
3. The motor is broken or the motor
wire is damaged and short circuit-
ed
4. The power board is damaged
1. Reset or redirect parameters
2. Check the machinery
3. Check and replace the motor
4. Replace the power board
E024 X axis encoder failure
1. It is reported as too fast when it is
moving.
2. Poor or damaged contact of the
encoder cable
3. The machine is stuck causing the
motor to turn
4. Motherboard is broken
5. The motor is broken
1. Decrease the idling speed
2. Check the wiring or replace the motor
3. Inspection machinery
4. Replace the motherboard
5. Replace the motor
E025 X axis disconnected
1. The motor plug is not inserted or
has poor contact
2. The motor wire is disconnected or
damaged
3. The motherboard is broken
1. Check the wiring
2. Replace the motor
3. Replace the motherboard
E026 X axis overload
The X axis is overloaded
Lighten the load
E027 X axis position deviation is
too large
Spare alarm
E028 X axis AD sampling module
failure
1. Abnormal startup
2. The motherboard is damaged
1. Restart
2. Replace the motherboard
E029 X axis overheated
Drive overload
Lighten the load
E030 Y axis overvoltage
Refer to
Error Handling Method
E031 Y axis undervoltage
Refer to
Error Handling Method
E032 Y axis hardware over cur-
rent
Refer to
Error Handling Method
E033 Y axis software over current
Refer to
Error Handling Method
E034 Y axis encoder failure
Refer to
Error Handling Method
E035 Y axis disconnected
Refer to
Error Handling Method
E036 Y axis overload
Refer to
Error Handling Method
E037 Y axis position deviation is
too large
Spare alarm
E038 Y axis AD sampling module
failure
Refer to
Error Handling Method
E039 Y axis overheated
Refer to
Error Handling Method
E040
Z axis overvoltage
Refer to
Error Handling Method
E041
Z axis undervoltage
Refer to
Error Handling Method
E042
Z axis hardware over cur
-
rent
Refer to
Error Handling Method
E043
Z axis software over current
Refer to
Error Handling Method
E044
Z axis encoder failure
Refer to
Error Handling Method
E045
Z axis disconnected
Refer to
Error Handling Method
E046
Z axis overload
Refer to
Error Handling Method
E047
Z axis position deviation is
too large
Spare alarm