59
−
1. The machine cannot be powered
up even though the power switch
has been turned ON.
2. The sewing machine motor fails to
rotate.
1
)
The transformer is not connected
properly.
2
)
There is no power to the
transformer.
3
)
The safety device of the drum
cover is actuated.
4)
Faulty contact of the power switch
5
)
The electromagnetic switch fails to
work.
1
)
The connector in the control box is
not properly connected.
2)
Defective detector
3)
The power is not turned ON.
4
)
The power cable has been
disconnected.
Fuse F1 has blown.
Fuse F2 has blown.
The power cable has been damaged.
The drum cover opens.
Faulty contact of the limit switch
Fuse F3 has blown.
Check the wiring.
Replace fuse F1.
Replace fuse F2.
Replace the cable.
Close the drum cover.
Check the cable.
Replace the switch.
Replace fuse F3.
Check whether the connector has been firmly connected.
Replace the detector.
Turn ON the power switch.
Check the connection of the power cable.
Troubles
Cause (1)
Cause (2)
Corrective measures